2017 methane emission detection and localization controlled release test at the Pacific Gas and Electric Livermore facility with sUAS
收藏DataONE2025-10-29 更新2025-11-01 收录
下载链接:
https://search.dataone.org/view/sha256:09ad982d681138860073c9b1eeb5cf4dd2cc282c93f58a3079278dc05163759e
下载链接
链接失效反馈官方服务:
资源简介:
In March of 2017, a series of methane release experiments were undertaken at the PG&E Livermore training facility over a three day period. A sUAS equipped with an Open Path Laser Spectrometer (OPLS) was flown and used to detect and localize the emission sources. The experiments included a variation of shared and blind configurations between the facility operators and the sUAS team. This data set include the flight trajectories, wind speed, and concentration measurements. , , # 2017 methane emission detection and localization controlled release test at the Pacific Gas and Electric Livermore facility with sUAS
Dataset DOI: [10.5061/dryad.h44j0zpxh](https://doi.org/10.5061/dryad.h44j0zpxh)
## Description of the data and file structure
This data set describes the measurement data collected during a 3 day controlled release test at the Pacific Gas and Electric Livermore Facility test site. The site consists of multiple residential style buildings with multiple leak sources for testing and training on leak detection technologies and standards.Â
The test configurations and leak locations are given in the following thesis:
Hollenbeck, D. (2023). Digital Twin Enabled Collective Sensing and Steering for Source Determination Problems. *UC Merced*.
([https://escholarship.org/uc/item/3vh5d81c](https://escholarship.org/uc/item/3vh5d81c)).
Additionally, the information can be found in:
Hollenbeck, D., & Chen, Y. (2025). Smart Sensing with Digital Twins: Methane Em...,
创建时间:
2025-10-30