five

Measuring short-chain per- and polyfluoroalkyl substances in Central New Jersey air using chemical ionization mass spectrometry

收藏
Taylor & Francis Group2024-06-26 更新2026-04-16 收录
下载链接:
https://tandf.figshare.com/articles/dataset/Measuring_short-chain_per-_and_polyfluoroalkyl_substances_in_Central_New_Jersey_air_using_chemical_ionization_mass_spectrometry/26080609/1
下载链接
链接失效反馈
官方服务:
资源简介:
Real-time measurements of short-chain (C &lt; 8) per- and polyfluoroalkyl substances (PFAS) were performed in Central New Jersey air using chemical ionization mass spectrometry (CIMS). The CIMS was calibrated for C<sub>2</sub> – C<sub>6</sub> perfluorinated carboxylic acids, and 4:2 and 6:2 fluorotelomer alcohols. Of these, only trifluoroacetic acid (TFA) was detected in ambient air above instrumental detection limits. However, instrumental sensitivities (and thus ambient mixing ratios) were estimated for other detected PFAS including C<sub>3</sub>H<sub>2</sub>F<sub>6</sub>O and C<sub>6</sub>HF<sub>11</sub>O<sub>3</sub>. TFA mixing ratios reached up to 0.7 parts-per-trillion by volume (pptv). Estimated C<sub>3</sub>H<sub>2</sub>F<sub>6</sub>O and C<sub>6</sub>HF<sub>11</sub>O<sub>3</sub> mixing ratios reached the single pptv level. These latter two formulas are consistent with hexafluoroisopropanol (HFIP) and hexafluoropropylene oxide dimer acid (HFPO-DA) respectively, though they may potentially represent multiple isomers. Diel profiles of detected PFAS, along with local meteorological data can provide information on potential local sources of these compounds. However, only limited discussion of potential sources was provided here given the sparse detection of these compounds above instrument detection limits. These results demonstrate the potential of online CIMS instrumentation for measuring certain PFAS in ambient outdoor air in real time at or below the pptv level. This technique also has potential for fenceline monitoring and other near-source applications. <i>Implications</i>: Online chemical ionization mass spectrometry (CIMS) has potential for fast, real-time measurements of certain airborne per- and polyfluoroalkyl substances (PFAS). Three short-chain (C &lt; 8) PFAS were detected by CIMS in Central New Jersey ambient air near or above the parts-per-trillion by volume (pptv) level. This technique also has potential for fenceline monitoring and other near-source applications for airborne PFAS.
提供机构:
Mattila, James M.; Offenberg, John H.
创建时间:
2024-06-21
二维码
社区交流群
二维码
科研交流群
商业服务