Thermal Analysis of Indoor Cooling Performance of the Thermoelectric Radiant Panel (TERP) System

收藏
NIAID Data Ecosystem2026-05-02 收录
下载链接:
https://data.mendeley.com/datasets/kdmh2zhtvc
下载链接
链接失效反馈
官方服务:
资源简介:
A thermal analysis of indoor cooling of the designed thermoelectric radiant panel (TERP) system is conducted to evaluate the system's capability to regulate temperature effectively. By analyzing its thermal performance, potential issues can be identified and addressed to optimize the indoor environment. The system is expected to perform reliably without significant temperature deviations in the indoor environment under tropical climate conditions. Detailed thermal analyses were performed using ANSYS software, which utilized the geometry of the target room with specific dimensions and exposure to heat sources, such as occupant-generated heat and solar radiation. In the analysis, the boundary conditions are set up as: (a) A steady state because this research focuses on evaluating the designed TERP system's performance at the minimum, average, and maximum outdoor temperatures in Malaysia, which are 25°C, 27°C, and 32°C, respectively. (b) The analysis is set up as laminar flow model since the air velocity in the target room is considered zero due to minimal or no air movement, given that the room is fully enclosed with all windows and doors tightly sealed at all times. (c) Only the ceiling and the east-facing wall and window are exposed to sunlight. Therefore, these façades are the only ones affected by outdoor temperature. (d) The temperature for the other walls, windows, floor, and door is set to 24°C, as they face the building's interior, where it is assumed that the adjacent rooms, the room below, and the pavement in front of the target room are also maintained at this temperature. Findings: The results are shown in the form of a 3D thermal profile, which uses color contours to represent temperature variations across the system and the target room. The analysis demonstrated that the TERP system could maintain indoor temperatures around 25°C, even during peak outdoor temperatures in Malaysia, even under extreme weather conditions. While high outdoor temperatures intensified uneven surface temperature distribution, this had minimal impact on overall indoor temperature stability. Furthermore, the panels exhibited a low risk of condensation due to surface temperatures consistently exceeding the indoor dew-point temperature. The results validate the TERP system's potential as an environmentally friendly alternative to conventional air conditioning systems, with applications particularly suited to tropical climates.
创建时间:
2025-02-26
二维码
社区交流群
二维码
科研交流群
商业服务