A previously undescribed scene-selective site is the key to encoding ego-motion in naturalistic environments
收藏NIAID Data Ecosystem2026-05-01 收录
下载链接:
http://datadryad.org/dataset/doi%253A10.5061%252Fdryad.xwdbrv1mj
下载链接
链接失效反馈官方服务:
资源简介:
Current models of scene processing in the human brain include three scene-selective areas: the Parahippocampal Place Area (or the temporal place areas; PPA/TPA), the restrosplenial cortex (or the medial place area; RSC/MPA) and the transverse occipital sulcus (or the occipital place area; TOS/OPA). Here, we challenged this model by showing that at least one other scene-selective site can also be detected within the human posterior intraparietal gyrus. Despite the smaller size of this site compared to the other scene-selective areas, the posterior intraparietal gyrus scene-selective (PIGS) site was detected consistently in a large pool of subjects (n=59; 33 females). The reproducibility of this finding was tested based on multiple criteria, including comparing the results across sessions, utilizing different scanners (3T and 7T) and stimulus sets. Furthermore, we found that this site (but not the other three scene-selective areas) is significantly sensitive to ego-motion in scenes, thus distinguishing the role of PIGS in scene perception relative to other scene-selective areas. These results highlight the importance of including finer scale scene-selective sites in models of scene processing – a crucial step toward a more comprehensive understanding of how scenes are encoded under dynamic conditions.
Methods
3T scans: In Experiments 1, 3a and 4-6, subjects were scanned in a horizontal 3T scanner (Tim Trio, Siemens Healthcare, Erlangen, Germany). Gradient echo EPI sequences were used for functional imaging. Functional data were acquired using single-shot gradient echo EPI with nominally 3.0 mm isotropic voxels (TR=2000 ms; TE=30 ms; flip angle=90°; band width (BW)=2298 Hz/pix; echo-spacing= 0.5 ms; no partial Fourier; 33 axial slices covering the entire brain; and no acceleration). During the first 3T scan (see the General Procedure), structural (anatomical) data were acquired for each subject using a 3D T1-weighted MPRAGE sequence (TR=2530 ms; TE=3.39 ms; TI=1100 ms; flip angle=7°; BW=200 Hz/pix; echo-spacing=8.2 ms; voxel size=1.0×1.0×1.33 mm).
7T scans: In Experiments 2 and 3b, subjects were scanned in a 7T Siemens whole-body scanner (Siemens Healthcare, Erlangen, Germany) equipped with SC72 body gradients (maximum gradient strength, 70 mT/m; maximum slew rate, 200 T/m/s) using a custom-built 32-channel helmet receive coil array and a birdcage volume transmit coil. Voxel dimensions were nominally 1.0 mm, isotropic. Single-shot gradient-echo EPI was used to acquire functional images with the following protocol parameter values: TR=3000 ms; TE=28 ms; flip angle=78°; BW=1184 Hz/pix; echo-spacing=1 ms; 7/8 phase partial Fourier; 44 oblique-coronal slices; and acceleration factor r=4 with GRAPPA reconstruction and FLEET-ACS data (Polimeni et al., 2015) with 10° flip angle. The field of view included the occipital-parietal brain areas to cover PIGS, RSC/MPA and TOS/OPA (but not PPA/TPA).
创建时间:
2024-03-14



