System identification of servo-hydraulic system with outer-loop control
收藏DataCite Commons2020-08-02 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2013-1225.groups/Experiment-2
下载链接
链接失效反馈官方服务:
资源简介:
The goal of this experiment is to evaluate the performance of actuator controllers in the frequency domain.
A band-limited white noise (BLWN) from 0 to 50 Hz with a displacement RMS of 0.254 mm was commanded to experimentally determine the servo-hydraulic system transfer function with outer-loop control. Controllers were designed to match the specimen conditions.
Variations include:
a. 0.0 Amps in damper, CDM controller
b. 0.0 Amps in damper, CDM w/FB controller
c. 2.5 Amps in damper, BDM controller
d. 2.5 Amps in damper, BDM w/FB controller with feedback
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2014-01-21