five

Identification of thresholds for accuracy comparisons of heart rate and respiratory rate in neonates

收藏
NIAID Data Ecosystem2026-03-12 收录
下载链接:
http://datadryad.org/dataset/doi%253A10.5061%252Fdryad.1c59zw3vb
下载链接
链接失效反馈
官方服务:
资源简介:
Background: Heart rate (HR) and respiratory rate (RR) can be challenging to measure accurately and reliably in neonates. The introduction of innovative, non-invasive measurement technologies suitable for resource-constrained settings is limited by the lack of appropriate clinical thresholds for accuracy comparison studies. Methods: We collected measurements of photoplethysmography-recorded HR and capnography-recorded exhaled carbon dioxide across multiple 60-second epochs (observations) in enrolled neonates admitted to the neonatal care unit at Aga Khan University Hospital in Nairobi, Kenya. Trained study nurses manually recorded HR, and the study team manually counted individual breaths from capnograms. For comparison, HR and RR also were measured using an automated signal detection algorithm. Clinical measurements were analyzed for repeatability. Results: A total of 297 epochs across 35 neonates were recorded. Manual HR showed a bias of -2.4 (-1.8%) and a spread between the 95% limits of agreement (LOA) of 40.3 (29.6%) compared to the algorithm-derived median HR. Manual RR showed a bias of -3.2 (-6.6%) and a spread between the 95% LOA of 17.9 (37.3%) compared to the algorithm-derived median RR, and a bias of -0.5 (1.1%) and a spread between the 95% LOA of 4.4 (9.1%) compared to the algorithm-derived RR count. Manual HR and RR showed repeatability of 0.6 (interquartile range (IQR) 0.5-0.7), and 0.7 (IQR 0.5-0.8), respectively. Conclusions: Appropriate clinical thresholds should be selected a priori when performing accuracy comparisons for HR and RR. Automated measurement technologies typically use a smoothing or averaging filter, which significantly impacts accuracy. A wider spread between the LOA, as much as 30%, should be considered to account for the observed physiological nuances and within- and between-neonate variability and different averaging methods. Wider adoption of thresholds by data standards organizations and technology developers and manufacturers will increase the robustness of clinical comparison studies. Methods We collected measurements of photoplethysmography-recorded heart rate (HR) and capnography-recorded exhaled carbon dioxide across multiple 60-second epochs (observations) in enrolled neonates. Trained study nurses manually recorded HR, and the study team manually counted individual breaths from capnograms. For comparison, HR and respiratory rate also were measured using an automated signal detection algorithm. Clinical measurements were analyzed for repeatability.
创建时间:
2021-10-03
二维码
社区交流群
二维码
科研交流群
商业服务