遇见数据集

ENDGAME - Laboratory Experiment 2024-01-17 Exp. 021 - High Speed Camera data

收藏
NIAID Data Ecosystem2026-05-02 收录
数据链接:
官方服务:

资源简介:

Shock-tube experiments in combination with high speed Schlieren shadow photography. The shocktube setup consists of a high-pressure reservoir connected with a cylindrical tube through a diaphragm pulse valve which allows a fast release of pressurized gas into the ambient pressure tube. The high-pressure reservoir is filled with compressed air at a given overpressure with respect to ambient pressure (up to 8 bar). The pipe was either empty (i.e. with air at ambient conditions) or filled with a given amount of small particles. We adopted pipes an inner diameter of 4 cm and different lengths (20, 30 and 80 cm). We also considered different volumes of pressurized gas (~650 cm3 and ~1550 cm3). A pressure sensor has been placed at the vent of the conduit to record pressure variations during experiments. Images from the high speed camera were collected at a frame rate of 30000 fps. When the valve is open, a jet flow is produced, with shock and acoustic waves propagating in the atmosphere, which become visible due to the high speed Schlieren shadow photography.

创建时间:
2024-08-22
二维码
社区交流群
二维码
科研交流群
商业服务