Dataset in support of the Southampton doctoral thesis 'MIR photodetection using intrinsic monolithic integrated germanium photodiodes'
收藏DataCite Commons2023-07-10 更新2025-04-17 收录
下载链接:
https://eprints.soton.ac.uk/478717/
下载链接
链接失效反馈官方服务:
资源简介:
This dataset contains: Data underpinning the tables and figures in the thesis Tab 1 – GC Losses These tables provide the data used to calculate the grating coupler losses for Table 7.1 in the thesis. Loss of the grating coupler is calculated as. Loss = 10*Log(Power_In/Power_Out) Tab 2 – GC Losses 3.8um These tables have the data used to calculate the GC losses at 3.8um for Fig 3.8 Tab 3 – 2um Prop Loss These tables have the data used to calculate the propagation loss of the waveguides using 2um light. Seen in figure 7.4 Tab 4 – 3.8um Prop Loss These tables have the data used to calculate the propagation loss of the waveguides using 3.8um light. Seen in figure 7.5 Tab 5 – 0V Resp This is the data used for figure 7.7. Tab 6 – IV Curve 2um This data is used for figure 7.8 Tab 7 – IV Curve 3.8um This data is used for figure 7.10 Tab 8 – VNA Freq This data is used for figure 7.12 Tab 9 – Linearity This data is used for figure 7.15 Tab 10 – Raman Graph This data is used for figure 7.16
提供机构:
University of Southampton
创建时间:
2023-07-10