ABSTRACT Purpose: To compare the use of visual field and/or optical coherence tomography (OCT) combined with color retinography by non-glaucoma specialists for differentiating glaucoma from physiological cupping. Methods: Eighty patients with glaucoma or physiological cupping (40 of each) were randomized according to the examination used (GI: color retinography, GII: color retinography + visual field, GIII: color retinography + optical coherence tomography, GIV: color retinography + visual field + optical coherence tomography). Twenty non-specialist ophthalmologists diagnosed glaucoma from PowerPoint slide images, without direct patient examination. Results: Inter-examiner agreement was good for GII (ĸ: 0.63; 95%CI, 0.53-0.72), moderate for GIII (ĸ: 0.58; 95%CI, 0.48-0.68) and GIV (ĸ: 0.41; 95%CI, 0.31-0.51), and low for GI (ĸ: 0.30; 95%CI, 0.20-0.39) (p