five

µCT data of two drill cores of fractured crystalline rock (Grimsel)

收藏
DataCite Commons2023-11-03 更新2025-04-16 收录
下载链接:
https://rodare.hzdr.de/record/2537
下载链接
链接失效反馈
官方服务:
资源简介:
Two crystalline rock drill cores from the Grimsel site were scanned with a Nikon XT H 225 - scanner. The samples were prepared (formatted and cast in epoxy) by UJV Rez, Czech Republic. The CT-data were acquired and processed at HZDR-FWOT. Sample 1 (GAM_UJV_1C_1) contains a complex system of interconnected fractures.<br> Sample 2 (GAM_UJV_1C_2) contains one single end-to-end fracture with larger aperture. Size of both samples: Diameter 80 mm, length 165 mm. Two tomograms were acquired for both samples:<br> 1) Complete drill core as one scan, voxel size ca. 75 µm.<br> 2) HR-tomogram merged from three sections with maximum resolution, voxel size ca. 40 µm. The tomograms were stored as 3D-raw files. Data format, acquisition parameters, and processing workflow, are documented in the tomogram header files (nrrd-format (text): see https://teem.sourceforge.net/nrrd/format.html).<br> This data format is importable into open-source visualization programs as 3D slicer (https://www.slicer.org) or Paraview (https://www.paraview.org). The data processing has been conducted with Avizo (https://www.thermofisher.com/de/de/home/electron-microscopy/products/software-em-3d-vis/avizo-software.html). Files:<br> Sample 1<br> GAM_UJV_1C_1_complet-2_01_NLM: Graylevel image of complete sample, ring artifact removal, non-local-means filter<br> GAM_UJV_1C_1_complet-2_01_thresholded: Tentative label image of complete sample, threshold segmentation with manual edit<br> Merged-GAM_UJV_1C_1_HR.Frac_section: Graylevel image of merged fracture section, unfiltered<br> Merged-GAM_UJV_1C_1_HR.Frac_section.Threshold: Tentative label image of merged fracture section, adaptive threshold segmentation with manual edit<br> GAM_UJV_1C_1_complet_2.png: Figure of complete sample <br> GAM_UJV_1C_1_HR_Frac_Y2.png: Figure of merged high-resolution tomogram Sample 2<br> GAM_UJV_1C_2_complet_01.filtered: Graylevel image of complete sample, ring artifact removal, non-local-means filter<br> GAM_UJV_1C_2_complet_01.filtered.thresholded: Tentative label image of complete sample, threshold segmentation with manual edit<br> Merged-GAM_UJV_1C_2_A_01.Frac_section.filtered: Graylevel image of merged fracture section, ring artifact removal, non-local-means filter<br> Merged-GAM_UJV_1C_2_A_01.Frac_section.filtered.segm: Tentative label image of merged fracture section, threshold segmentation with manual edit<br> GAM_UJV_1C_2_complett_2.png: Figure of complete sample<br> GAM_UJV_1C_2_HR_Frac_Y2.png: Figure of merged high-resolution tomogram Original acquistion data are stored on the HZDR bulk data storage system and available for reprocessing on request. <br> Financial support was granted from the European Union’s Horizon 2020 research and innovation program under grant agreement No. 847593 (EURAD, WP FUTURE, task 2.2).<br>
提供机构:
Rodare
创建时间:
2023-11-03
二维码
社区交流群
二维码
科研交流群
商业服务