遇见数据集

Supplementary information files for A strategy for CO<sub>2</sub> capture and utilization towards methanol production at industrial scale: an integrated highly efficient process based on multi-criteria assessment

收藏
DataCite Commons2024-02-20 更新2024-07-13 收录
官方服务:

资源简介:

© the Authors CC-BY 4.0Supplementary files for article A strategy for CO<sub>2</sub> capture and utilization towards methanol production at industrial scale: an integrated highly efficient process based on multi-criteria assessmentCO<sub>2</sub> capture and utilization are an effective solution to the problem of CO<sub>2</sub> emissions, and a combination of ammonia-based CO<sub>2</sub> capture and its use for methanol production is a highly feasible strategy. However, the uses of conventional technologies have resulted in a high demand for energy, with limited use of hydrogen. To address these problems, an innovative strategy is proposed and demonstrated in this study that enhances the conventional design, i.e., to use ammonia-based CO<sub>2</sub> capture with double tower absorption and solvent split, along with wet hydrogen for methanol production at industrial scale. The process is further improved through a multi-criteria assessment that considered the CO<sub>2</sub> capture rate, NH<sub>3</sub> loss rate, CO<sub>2</sub> conversion rate, and energy saving factors, in which the latter is based on two components, namely the reboiler duty and the condenser duty. Moreover, an exergy analysis method is used to optimize the improved process, and a highly efficient integrated process is finally established. It has been found that the use of a double-tower absorption process ensures high rates of CO<sub>2</sub> capture and low rates of NH<sub>3</sub> loss. Additionally, adjusting the molar ratio of H<sub>2</sub> to CO<sub>2</sub> leads to an impressive 8% increase in the CO<sub>2</sub> conversion rate, reaching 25%. In terms of energy savings, the average reboiler duty was reduced from 13.39 to 11.85 MJ/kg<sub>CO2</sub>, i.e., by 11.50%; while the condenser duty was reduced by 11.36%; both contributed to the overall energy savings. In the I-ACCMP process, the total exergy loss is 437.24 kW, of which the exergy loss of the heat exchangers accounts for 16%, and the desorption tower (DES) accounts for 48%. After optimization, the exergy loss of the heat exchangers decreases from 70.02 kW to 40.45 kW, the exergy loss of the DES decreases from 209.29 kW to 180.91 kW, and the reboiler duty is reduced from 10.60 MJ/kg<sub>CO2</sub> to 7.71 MJ/kg<sub>CO2</sub>. The total exergy loss decreases from 437.24 kW to 372.68 kW, which is a reduction by 14.8%.

创建时间:
2024-02-20
二维码
社区交流群
二维码
科研交流群
商业服务