five

NeuroSpin hMT+ Localizer DATA (MEG & aMRI)

收藏
OpenNeuro2020-11-20 更新2026-03-14 收录
下载链接:
https://openneuro.org/datasets/ds003392
下载链接
链接失效反馈
官方服务:
资源简介:
Dataset description: Magnetoencephalography (MEG) dataset recorded during a hMT+ (human visual motion area) localizer task Published in: Zilber, N., Ciuciu, P., Gramfort, A., Azizi, L., & Van Wassenhove, V. (2014). Supramodal processing optimizes visual perceptual learning and plasticity. Neuroimage, 93, 32-46. Data curation: Sophie Herbst, Alexandre Gramfort This MEG dataset was prepared in the Brain Imaging Data Structure (MEG-BIDS, Niso et al. 2018) format using MNE-BIDS (Appelhoff et al. 2019). The dataset contains 10 of the 12 participants from the vision-only training group. Two participants were removed, one due to problems with the trigger channel, and one due to different settings in the acquisition preventing us from processing the dataset without prior adjustment. ## EXPERIMENT Participants were presented with a cloud of moving dots, always starting with incoherent movement (up or down result in equal display, due to the incoherence). After 500 ms, the movement became coherent in 50% of the trials (95% coherence, up or down) and remained incoherent in the other 50%, lasting for 1000 ms. Participants were instructed to passively view the stimuli for a total of 120 trials. Events: 1: coherent / down 2: coherent / up 3: incoherent / down 4: incoherent / up ## MEG Brain magnetic fields were recorded in a MSR using a 306 MEG system (Neuromag Elekta LTD, Helsinki). MEG recordings were sampled at 2 kHz and band-pass filtered between 0.03 and 600 Hz. Four head position coils (HPI) measured the head position of participants before each block; three fiducial markers (nasion and pre-auricular points) were used for digitization and anatomicalMRI (aMRI) immediately following MEG acquisition. Electrooculograms (EOG, horizontal and vertical eye movements) and electrocardiogram (ECG) were simultaneously recorded. Prior to the session, 5 min of empty room recordings was acquired for the computation of the noise covariance matrix. Bad MEG channels were marked manually. ## MRI The T1 weighted aMRI was recorded using a 3-T Siemens Trio MRI scanner. Parameters of the sequence were: voxel size: 1.0 × 1.0 × 1.1 mm; acquisition time: 466 s; repetition time TR = 2300 ms; and echo time TE = 2.98 ms ## References Zilber, N., Ciuciu, P., Gramfort, A., Azizi, L., & Van Wassenhove, V. (2014). Supramodal processing optimizes visual perceptual learning and plasticity. Neuroimage, 93, 32-46. Appelhoff, S., Sanderson, M., Brooks, T., Vliet, M., Quentin, R., Holdgraf, C., Chaumon, M., Mikulan, E., Tavabi, K., Höchenberger, R., Welke, D., Brunner, C., Rockhill, A., Larson, E., Gramfort, A. and Jas, M. (2019). MNE-BIDS: Organizing electrophysiological data into the BIDS format and facilitating their analysis. Journal of Open Source Software 4: (1896). https://doi.org/10.21105/joss.01896 Niso, G., Gorgolewski, K. J., Bock, E., Brooks, T. L., Flandin, G., Gramfort, A., Henson, R. N., Jas, M., Litvak, V., Moreau, J., Oostenveld, R., Schoffelen, J., Tadel, F., Wexler, J., Baillet, S. (2018). MEG-BIDS, the brain imaging data structure extended to magnetoencephalography. Scientific Data, 5, 180110. http://doi.org/10.1038/sdata.2018.110
创建时间:
2020-11-20
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作