DETERMINATION OF MERCURY IN LIVER OF MARINE TETRAPODS BY COLD VAPOR ATOMIC FLUORESCENCE SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY IN BIOLOGICAL SAMPLES: A SYSTEMATIC COMPARISON BETWEEN THE TWO TECHNIQUES

收藏
NIAID Data Ecosystem2026-05-10 收录
下载链接:
https://figshare.com/articles/dataset/DETERMINATION_OF_MERCURY_IN_LIVER_OF_MARINE_TETRAPODS_BY_COLD_VAPOR_ATOMIC_FLUORESCENCE_SPECTROMETRY_AND_INDUCTIVELY_COUPLED_PLASMA_MASS_SPECTROMETRY_IN_BIOLOGICAL_SAMPLES_A_SYSTEMATIC_COMPARISON_BETWEEN_THE_TWO_TECHNIQUES/14279125
下载链接
链接失效反馈
官方服务:
资源简介:
This study compares the techniques cold vapour atomic fluorescence spectrometry (CV-AFS) and inductively coupled plasma mass spectrometry (ICP-MS) for the determination of Hg in biological samples (hepatic tissue from marine tetrapods). Acid digestions were performed for the samples and aliquots of them were analysed by ICP-MS and CV-AFS. To minimize the Hg memory effect in its determination by ICP-MS, gold (200 µg L-1 in 5% v v-1 HCl) was added to the sample digests. The detection limits were 0.02 mg kg-1 for ICP-MS and 0.01 mg kg-1 for CV-AFS. Accuracy was assessed by the calculation of the recovery obtained from TORT-3 (lobster hepatopancreas) certified reference material analysis. Accurate results were obtained for both CV-AFS and ICP-MS. The comparison of the results obtained for hepatic tissue with and without lyophilization showed a significant difference among them (at 95% of confidence level), evidencing losses of Hg in the lyophilization process.