Pulp chamber temperature rise in light-cure bonding of brackets with and without primer, in intact versus restored teeth

收藏
Figshare2023-06-01 更新2026-04-28 收录
下载链接:
https://figshare.com/articles/dataset/Pulp_chamber_temperature_rise_in_light-cure_bonding_of_brackets_with_and_without_primer_in_intact_versus_restored_teeth/23300480
下载链接
链接失效反馈
官方服务:
资源简介:
ABSTRACT Objective: To evaluate the pulp chamber temperature rise (PCTR) in light-cure bonding of brackets with and without primer, in intact and restored mandibular central incisors (M1), maxillary first premolars (Mx4), and mandibular third molars (M8). Material and Methods: Ninety human teeth were included: M1 (n=30), Mx4 (n=30), and M8 (n=30). Light-cure bonding of brackets was performed in intact (n=60) and restored (n=30) teeth, with primer (n=60) or without (n=30) primer. PCTR was defined as the difference between initial (T0) and peak temperatures (T1), recorded with a thermocouple during light-cure bonding. Differences on PCTR between bonding techniques (primer vs. no primer), teeth types (M1 vs. Mx4 vs. M8), and teeth condition (intact vs. restored) were estimated by ANCOVA, with α=5%. Results: PCTR was significantly higher with the use of primer (2.05 ± 0.08oC) than without primer (1.65 ± 0.14oC) (p=0.02), and in M1 (2.23 ± 0.22oC) compared to Mx4 (1.56 ± 0.14oC) (p0.05), and no difference between intact (1.78 ± 0.14oC) and restored (1.92 ± 0.08oC) teeth (p=0.38). There was no influence of dentin enamel thickness in the PCTR (p=0.19). Conclusion: PCTR was higher in light-cure bonding of brackets with primer, especially in M1. Light-cure bonding seems less invasive without primer.