EMUE-D4-2-OrificePlate
收藏资源简介:
The report shows how the uncertainty should be evaluated for a measurement from an orifice meter where the flowrate is evaluated using a discharge-coefficient equation based on data from a population of orifice meters: the orifice meter in service is not itself calibrated in a flowing fluid, but is similar (with permitted variability) to those on which the discharge-coefficient equation is based. The data on which the discharge-coefficient equation in ISO 5167-2:2003 (the Reader-Harris/Gallagher (1998) Equation) is based are given in the uploaded dataset together with the analysis required by the report (to follow). Files contained in the dataset are: D4-2_Report.pdf: Report “The uncertainty of the orifice-plate discharge coefficient” D4-2 LaTeX Source Files.zip: LaTeX files to be compiled in order to produce D4-2_Report.pdf. D4-2_Figures.zip: figures/graphs from the report, including data points. EMUE-D4-2-OrificePlate.xlsm: Excel spreadsheet containing all data associated with the example.