3D modeling and 4D flow data of total cavopulmonary connection (TCPC) vs. convergent cavopulmonary connection (CCPC)
收藏DataONE2024-02-19 更新2024-06-08 收录
下载链接:
https://search.dataone.org/view/sha256:d4bce8f8c6831504f5058cb5c932e84d2863a8a1f826d91b296a6d694667e4db
下载链接
链接失效反馈官方服务:
资源简介:
This study conducts a comprehensive evaluation focused on assessing the feasibility and validation of patient-specific convergent cavopulmonary connection (CCPC) grafts for individuals with congenital heart defects in comparison with the performance of total cavopulmonary connection (TCPC) grafts. The datasets incorporated in this submission constitute crucial information enabling comprehension of our methodology and replication of our experiments using a mock circulatory flow loop. These datasets encompass 3D models, flow rates, basic demographic information, and 4D Flow DICOMs of 11 TCPC models. Additionally, raw CSV measurements from a 4D Flow software for both CCPC and TCPC grafts have been included. By means of the development and analysis of these datasets, we have effectively demonstrated the non-inferiority of the CCPC configuration compared to the TCPC design. The CCPC modifications to the Fontan design did not incur additional hemodynamic costs and provided improvements in hep..., Patients diagnosed with congenital heart defects and requiring TCPC grafts were selected for this study. The TCPC grafts were initially imaged using magnetic resonance imaging (MRI) techniques. Subsequently, the MRI data were processed utilizing segmentation software  Mimics Medical (materialise.com), to meticulously segment and extract the TCPC grafts, generating STL files representing the three-dimensional structure of the grafts. The TCPC grafts were then 3D printed. In vitro testing was then performed via a custom mock circulatory flow loop. A solution of 60% water and 40% glycerin was used to mimic blood viscosity. An MRI-compatible pump (CardioFlow 5000 MR, Shelley) was used to recreate the patientsâ cardiac output and was held constant throughout testing. Four ultrasonic flow meters (Onicon, Largo, FL) were used to measure the flow of the inlets at the IVC and SVC and the outlets at the left and right pulmonary arteries (LPA and RPA, respectively). Ball valves were used to achiev..., , # 3D modeling and 4D flow data of Total Cavopulmonary Connection (TCPC) vs. Convergent Cavopulmonary connection (CCPC)
This study conducts a comprehensive evaluation focused on assessing the feasibility and validation of patient-specific convergent cavopulmonary connection (CCPC) grafts for individuals with congenital heart defects in comparison with the performance of total cavopulmonary connection (TCPC) grafts. The datasets incorporated in this submission constitute crucial information enabling comprehension of our methodology and replication of our experiments using a mock circulatory flow loop. These datasets encompass 3D models, flow rates, basic demographic information, and 4D Flow DICOMs of 11 TCPC models. Additionally, raw CSV measurements from a 4D Flow software for both CCPC and TCPC grafts have been included. By means of the development and analysis of these datasets, we have effectively demonstrated the non-inferiority of the CCPC configuration compared to the TCPC desig...
创建时间:
2025-07-27



