CSU Atmospheric Science Parsival disdrometer data - ATS roof deployment
收藏DataONE2025-10-25 更新2025-11-01 收录
下载链接:
https://search.dataone.org/view/sha256:9cb0c2c1d1278d6e69b8190b8cc43d8fb0614de9da9376edbab0fe721aede395
下载链接
链接失效反馈官方服务:
资源简介:
This dataset contains the OTT Disdrometer data for the instrument when it was deployed on the roof of the Colorado State University Department of Atmospheric Science Main building. The instrument was initially installed in June of 2018 and collected data until January 2022, when it was moved for a field project. Between 6/21/2018 and 1/19/2022, there are many missing days due to outages and failures. The raw data are provided here along with python code to read and plot the raw data. The data are binned by fall speed and diameter, and also include precipitation rates, number of particles, and weather codes.
, An OTT Parsivel 2 Disdrometer was installed on the roof of the Department of Atmospheric Science (ATS) Main Building at the Foothills Campus of Colorado State University. This disrometer was placed on an unobstructed instrument platform. The position of this location is approximately 40.5879 °N, 105.1476 °W with an altitude of ~1,595 m (5233 ft). The instrument was deployed at this position from 6/21/2018 through to 1/19/2022, after which the instrument was deployed on several field campaigns (PRECIP, BACS). The data is processed through OTTâs ASDO software.
, # CSU Atmospheric Science Parsival disdrometer data - ATS roof deployment
Dataset DOI: [10.5061/dryad.dz08kpsb9](https://doi.org/10.5061/dryad.dz08kpsb9)
## Description of the data and file structure
**File format:**\
The data are provided in a zipped tar file called csuats_ott.tar.gz
Inside the tar file are CSV (Comma-separated values) files for each day with the filename structure of: YYYYMMDD.CSUATS.MIS
**Missing and bad data:**
This dataset does not represent a continuous timeseries from installation in Jun 2018 through Jan 2022. At times the disdrometer was offline. During periods when it was offline, there are no data recorded and times and/or entire day files will be missing.
When the disdrometer is collecting data but does not detect any precipitation, the reflectivity (Column 8) is set to -9.999 and the spectrum columns (17 onward) will not be present. If there is precipitation detected, the columns in the spectrum will be empty if there is nothing detected in that bin.
...,
创建时间:
2025-10-25