Experimental researches on the performance of a rotary-type magnetic refrigerator with double-Halbach permanent magnet arrays.

收藏
DataCite Commons2020-09-20 更新2025-04-16 收录
下载链接:
http://iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0025034&DOCBASE=IFD_REFDOC_EN&SETLANGUAGE=EN
下载链接
链接失效反馈
官方服务:
资源简介:
A room-temperature rotary-type magnetic refrigerator based on previous experiences is designed and constructed with a modified double-Halbach permanent magnet arrays. When the inner magnet array is periodically rotated, the average magnetic field provided by the new magnet system ranges from 0.04 T to 1.50 T in the centre region of the inner bore along 70% length of magnet arrays. This is fairly superior to the average value of previous magnetic arrays, which ranges from 0.3 T to 1.2 T. Influence of the magnetic field strength on the refrigerating performance have been discussed and studied. A series of experiments based on Gadolinium have been done to investigate the system performance including no-load temperature span and cooling power, with different frequencies and utilization factors.
提供机构:
International Institute of Refrigeration (IIR)