five

Serum Protein Risk Stratification Score for Diagnostic Evaluation of Metabolic Dysfunction-Associated Steatohepatitis (MASH)

收藏
NIAID Data Ecosystem2026-05-02 收录
下载链接:
https://www.ncbi.nlm.nih.gov/geo/query/acc.cgi?acc=GSE251855
下载链接
链接失效反馈
官方服务:
资源简介:
Reliable non-invasive tools to diagnose at risk metabolic dysfunction-associated steatohepatitis (MASH) are urgently needed to improve management. We developed a risk stratification score incorporating proteomics-derived serum markers with clinical variables to identify high risk MASH patients (NAFLD Activity Score (NAS) >4 and fibrosis score >2). In this three-phase proteomic study of biopsy-proven metabolic dysfunction-associated steatotic fatty liver disease (MASLD), we first developed a multi-protein predictor for discriminating NAS>4 based on SOMAscan proteomics quantifying 1,305 serum proteins from 57 US patients. Four key predictor proteins were verified by ELISA in the expanded US cohort (N=168), and enhanced by adding clinical variables to create the 9-feature MASH Dx Score which predicted MASH and also high risk MASH (F2+). The MASH Dx Score was validated in two independent, external cohorts from Germany (N=139) and Brazil (N=177). The discovery phase identified a 6-protein classifier that achieved an AUC of 0.93 for identifying MASH. Significant elevation of four proteins (THBS2, GDF15, SELE, IGFBP7) was verified by ELISA in the expanded discovery and independently in the two external cohorts. MASH Dx Score incorporated these proteins with established MASH risk factors (age, BMI, ALT, diabetes, hypertension) to achieve good discrimination between MASH and MASLD without MASH (AUC:0.87- discovery; 0.83- pooled external validation cohorts), with similar performance when evaluating high risk MASH F2-4 (vs. MASH F0-1 and MASLD without MASH). The MASH Dx Score offers the first reliable non-invasive approach combining novel, biologically plausible ELISA-based fibrosis markers and clinical parameters to detect high risk MASH in patient cohorts from the US, Brasil and Europe. Serum samples (57), five pooled serum controls, and one buffer control were analyzed using the SOMAscan Assay Kit for human serum 1.3k, measuring expression of 1,305 proteins according to the manufacturer’s standard protocol (SomaLogic; Boulder, CO). Data quality control, normalization, and calibration were done according to the manufacturer’s protocol.
创建时间:
2025-01-24
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作