five

Maximum temperature data from thermal safety assessment of type 21700 lithium-ion batteries with NMC, NCA and LFP cathodes by means of Accelerating Rate Calorimetry (ARC)

收藏
NIAID Data Ecosystem2026-05-01 收录
下载链接:
https://zenodo.org/record/7867729
下载链接
链接失效反馈
官方服务:
资源简介:
Data of safety investigation and thermal abuse behavior of commercial type 21700 LIB cells is provided. It has been acquired with Accelerating Rate Calorimetry (ARC), using a Thermal Hazard Technology type ES ARC. Moreover, thermal abuse was done by means of the so-called Heat-Wait-Seek (HWS) test, at different states of charge (SOC) from 0 to 100. Different cathode chemistries are compared (NMC, NCA and LFP), as well as for NCA chemistry, the high energy (HE) and high power (HP) cell design. For each cell, data includes the maximum temperature measured during thermal abuse at the surface on the center of the cell. Additionally, the mean value and standard deviation for each cell type and state of charge is provided. This data is supporting this article in the journal Batteries: https://doi.org/10.3390/batteries9050237 Additional supporting material to this article are the exothermal data for thermal abuse, that are published here: https://doi.org/10.5281/zenodo.7707929
创建时间:
2023-04-26
二维码
社区交流群
二维码
科研交流群
商业服务