遇见数据集

Rapid Early Inactivation and Ventilation-Driven Removal of Cough-Generated E. coli Aerosols in a Room-Scale Chamber

收藏
Zenodo2026-09-14 更新2026-10-01 收录
官方服务:

资源简介:

Dataset: Rapid Early Inactivation and Ventilation-Driven Removal of Cough-Generated E. coli Aerosols in a Room-Scale Chamber — Particle and Bioaerosol Data Description This repository contains all data associated with the figures in the main manuscript and the Supporting Information. The dataset includes experimental particle concentration measurements and culturable bioaerosol (Escherichia coli) data collected under controlled indoor conditions across a range of relative humidity levels and source-to-receptor distances. Files Particle Data Particle concentrations were measured at fixed sampling intervals with 31 size bins. Unless otherwise noted, measurements were taken at 1.2 m height (same height as the source). File RH Distance Height Sampling interval raw_particle_30RH_1m 30% 1 m 1.2 m (source height) 6 s raw_particle_50RH_1m 50% 1 m 1.2 m (source height) 6 s raw_particle_50RH_2m 50% 2 m 1.2 m (source height) 6 s raw_particle_50RH_3m 50% 3 m 1.2 m (source height) 6 s raw_particle_50RH_4m 50% 4 m 1.2 m (source height) 6 s raw_particle_70RH_1m 70% 1 m 1.2 m (source height) 6 s raw_deposition_particle_50RH_2m 50% 2 m Ground level 6 s raw_deposition_particle_50RH_4m 50% 4 m Ground level 6 s raw_cough_particle_50RH_1m 50% 1 m 1.2 m (source height) 1 s E. coli Data andersendata.csv Used in: Figure 2B and Figure 3 Size-resolved bioaerosol concentrations collected with an Andersen six-stage cascade impactor. Each row corresponds to one petri dish placed under a single impactor stage. Column Description STAGE Andersen impactor stage number. DILUTION Dilution factor COUNT Number of colony-forming units (CFU) counted on the petri dish. SAMPLE Sample identifier. TIME Time at which the sample was collected. REPLICATE Replicate number for the experimental run. petridishmachine.csv Used in: Figure 5A Passive bioaerosol deposition data collected by exposing open petri dishes at defined distances from the aerosol source. Column Description PETRI DISH Petri dish identifier number. COUNT Number of colony-forming units (CFU) counted on the petri dish. NORMALIZED CFU count normalized to surface area (CFU m⁻²). SAMPLE TIME Start time of the petri dish exposure period (hours) TIME Duration of exposure (hours). REPLICATE Replicate number for the experimental run. DISTANCE Distance of the petri dish from the coughing machine (meters) Notes Particle data files contain 31 size bins measured at fixed time intervals; bin size ranges and units are defined in the instrument manufacturer's documentation. Colony counts represent culturable E. coli only; viable-but-non-culturable fractions are not captured. Raw colony counts (COUNT) in andersendata.csv should be corrected for the DILUTION factor before calculating absolute concentrations. NORMALIZED values in petridishmachine.csv have already been adjusted for petri dish surface area.

提供机构:
Zenodo
创建时间:
2026-09-14
二维码
社区交流群
二维码
科研交流群
商业服务