Clinical validation of a smartphone-based handheld fundus camera for the evaluation of optic nerve head

收藏
Mendeley Data2024-06-25 更新2024-06-29 收录
下载链接:
https://scielo.figshare.com/articles/dataset/Clinical_validation_of_a_smartphone-based_handheld_fundus_camera_for_the_evaluation_of_optic_nerve_head/19925838
下载链接
链接失效反馈
官方服务:
资源简介:
ABSTRACT Purpose: To compare the quality of retinal images captured with a smartphone-based, handheld fundus camera with that of retinal images captured with a commercial fundus camera and to analyze their agreement in determining the cup-to-disc ratio for a cohort of ophthalmological patients. Methods: A total of 50 patients from a secondary ophthalmic outpatient service center underwent a bilateral fundus examination under mydriasis with a smartphone-based, handheld fundus camera and with a commercial fundus camera (4 images/patient by each). Two experienced ophthalmologists evaluated all the fundus images and graded them on the Likert 1-5 scale for quality. Multivariate regression analyses was then performed to evaluate the factors associated with the image quality. Two masked ophthalmologists determined the vertical cup-to-disc ratio of each fundus image, and both the intraobserver (between devices) and interobserver agreement between them was calculated. Results: Ninety-eight images from 49 patients were processed in this study for their quality analysis. Ten images from five patients (four from commercial fundus camera and one from smartphone-based, handheld fundus camera) were not included in the analyses due to their extremely poor quality. The medians [interquartile interval] of the image quality were not significantly different between those from the smartphone-based, handheld fundus camera and from the commercial fundus camera (4 [4-5] versus 4 [3-4] respectively, p=0.06); however, both the images captured with the commercial fundus camera and the presence of media opacity presented a significant negative correlation with the image quality. Both the intraobserver [intraclass correlation coefficient (ICC)=0.82, p<0.001 and 0.83, p<0.001, for examiners 1 and 2, respectively] and interobserver (ICC=0.70, p=0.001 and 0.81; p<0.001, for smartphone-based handheld fundus camera and commercial fundus camera, respectively) agreements were excellent and statistically significant. Conclusions: Our results thus indicate that the smartphone-based, handheld fundus camera yields an image quality similar to that from a commercial fundus camera, with significant agreement in the cup-to-disc ratios between them. In addition to the good outcomes recorded, the smartphone-based, handheld fundus camera offers the advantages of portability and low-cost to serve as an alternative for fundus documentation for future telemedicine approaches in medical interventions.
创建时间:
2023-06-28
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作