BIFID_CONDYLE_FEM_ORTHOTROPIC
收藏资源简介:
The dataset comprises the complete pre- and post-processing computational environments utilised to evaluate the biomechanical response of the bifid mandibular condyle under physiological loading. The repository includes the fully parameterised finite element model (.fsm) and the corresponding simulation output database (.xplt), both native to the FEBio software suite. The .fsm file encapsulates the entire numerical architecture, explicitly defining the spatial discretisation, kinematic boundary conditions, multiaxial loading vectors, and the orthotropic constitutive models governing the osseous tissue mechanics. The .xplt file archives the resolved computational state, providing high-fidelity nodal and elemental field outputs for structural deformation, strain, stress distribution, and strain energy density.