five

Daily Living Activity Recognition Using Wearable Devices: A Features-rich Dataset and a Novel Approach

收藏
NIAID Data Ecosystem2026-03-12 收录
下载链接:
https://doi.org/10.7910/DVN/G23QTS
下载链接
链接失效反馈
官方服务:
资源简介:
This dataset contains three-axial accelerometer, magnetometer, and gyroscope data recorded from different parts of the body: dominant wrist, hip, and ankle while performing 17 different daily-life activities. All data were recorded with medical-grade devices at a high sampling frequency (up to 256Hz). The dataset includes data of 8 volunteers, aged between 23-37, with a weight between 52-90 kg and height between 172-186 cm. All the subjects were healthy. Each person performed 17 different activities: (Set A Activities): RELAX, KEYBOARD, LAPTOP, HANDWRITING, HANDWASHING, FACEWASHING, TEETHBRUSH, SWEEPING, VACUUMING, EATING, DUSTING, RUBBING (Set B Activities): DOWNSTAIRS, WALKING, WALKING FAST, UPSTAIRS, UPSTAIRS FAST Set A activities have been performed for a fixed time, while Set B not. In particular, Set A activities have been performed for more than 120 seconds (in general for about 150 seconds), and we labelled in the dataset the central 120 seconds of each execution in order to obtain cleaner data. On the other hand, Set B includes: WALKING performed for 160 meters (in at least 110 seconds); WALKING_FAST performed for 205 meters (in at least 110 seconds); DOWNSTAIRS, UPSTAIRS, UPSTAIRS_FAST performed using a single flight of stairs with no intermediate floors between the steps for an average time of 40 seconds. While performing these activities, the subjects were wearing these three devices with the following settings: 1 Actigraph Centrepoint at the dominant wrist. Accelerometer recording at a sampling rate of 256Hz 1 Actigraph GT9X Link at the right hip at the height of the iliac crest (using the device belt clip). IMU (i.e., accelerometer, magnetometer, and gyroscope) recording at a sampling rate of 100Hz. 1 Actigraph GT9X Link at the height of the right ankle placed, with the help of the belt clip, on the subject's right side of the shoe, over the malleolus. IMU recording at a sampling rate of 100Hz. In any work using this dataset cite the related publication. The publication reports detailed information concerning the procedure followed for recording the dataset. Additional information and detailed biometric data of each subjects are, respectively, in the README.txt and subjects_info.csv files.
创建时间:
2021-02-24
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作