Magnetic Core Loss with Superimposed DC Bias
收藏DataCite Commons2022-07-20 更新2025-04-16 收录
下载链接:
https://ieee-dataport.org/documents/magnetic-core-loss-superimposed-dc-bias
下载链接
链接失效反馈官方服务:
资源简介:
This dataset aims to provide more insight into magnetic core losses at high frequency (MHz range) with superimposedDC bias in ferrites. The tested MnZn ferrite has a nominal relative permeability of 1500 (PC50) and 800 (PC200), which was tested at frequency from 500 kHz to 3 MHz.The DC bias appears to create a shift in the Steinmetz parameters, in particular the ki and β are affected the most.Higher DC bias creates higher losses gain and higher operating frequency makes the relative losses increase lower.Finally, the Steinmetz Premagnetization Graph (SPG) + iGSE method and Artificial Neural Network (ANN) method are used to create a core losses prediction model.As the result, the maximum error of 20% and 37% were found for SPG and ANN method respectively, while the average errors are 5.4% and 7%.
提供机构:
IEEE DataPort
创建时间:
2022-07-20