Safety analysis of the 100 kA HTS current lead for CFETR
收藏科学数据银行2022-10-20 更新2026-04-23 收录
下载链接:
https://www.scidb.cn/detail?dataSetId=44d0087a0b8441a08702bdf00197978e
下载链接
链接失效反馈官方服务:
资源简介:
Based on the Agreement of Institute of Plasma Physics Chinese Academy of Sciences (ASIPP) and Ministry of Science and Technology of China during the Thirteen Five-Years Plan (so called 13∙5 plan), a dedicated test facility of superconducting magnet for China Fusion Engineering Test Reactor (CFETR) will be constructed in Hefei, China. A pair of high temperature superconducting (HTS) current leads rated at 100 kA for the CFETR magnet test facility is being designed at ASIPP. Because magnetic energy stored in the toroidal fifield magnet iS 134 Giga Joules which are 3 times higher than the ITER case, HTS current leads must work at nominal current without performance degradation during the HTS current lead quench. In order to verify the safety and reliability of HTS current lead, the analysis of static magnetic fifield is done by ANSYS iteration to predict the maximum current carrying capacity of HTS module. This paper also give the numerical calculation of loss of flflow accident(LOFA) of HTS current lead and temperature margin analysis of HTS module. The analysis results indicate that the HTS module has a current carrying capacity of 165 kA without external fifield at 65 K and a current carrying capacity of 149 kA with external 30 mT vertical fifield at 65 K. The LOFA time is about 580 s and the burnout time is about 30 s, which is better than the requirement of the toroidal fifield coil fast discharge time of 24 s.
提供机构:
中国科学院等离子体物理研究所
创建时间: