遇见数据集

Test data for the eitprocessing software package

收藏
Zenodo2025-11-12 更新2026-05-26 收录
官方服务:

资源简介:

Healthy volunteer data used for testing the eitprocessing software. This data was specifically collected for this purpose, or selected from existing datasets. All data has been published with the explicit permission of the subject and data owner. Annotations: draeger_20Hz_healthy_volunteer.bin - Recorded using the Dräger Pulmovista V500 at 20Hz sample frequency, using software V1.3. Semi-recumbent position. Chaotic breathing, talking, movement artifacts. draeger_20Hz_healthy_volunteer_fixed_rr.bin - Recorded using the Dräger Pulmovista V500 at 20Hz sample frequency, using software V1.3. Semi-recumbent position. Duration: ~6 minutes. ~2 minutes at a fixed 10 breaths per minute, ~2 minutes with changing respiratory rate, and finally ~2 minutes at a fixed 15 breaths per minute. draeger_20Hz_healthy_volunteer_pressure_pod.bin - Recorded using the Dräger Pulmovista V500 at 20Hz sample frequency, using software V1.3. Semi-recumbent position. Short section of quiet breathing with (unrelated!) pressure pod data measured simultaneously. draeger_50Hz_healthy_volunteer_pressure_pod.bin - Recorded using the Dräger Pulmovista V500 at 50Hz sample frequency, using software V1.3. Semi-recumbent position. Short section of quiet breathing with (unrelated!) pressure pod data measured simultaneously. draeger_20Hz_healthy_volunteer_time_wrap_v120.bin - Recorded using the Dräger Pulmovista V500 at 20Hz sample frequency, using software V1.3, but exported using the V1.2 software. Recorded around midnight (starting before, ending after 0:00) for testing the time wrapping back to 0. Upright sitting position. Short section of regular breathing. draeger_20Hz_healthy_volunteer_time_wrap_v120.bin - Recorded using the Dräger Pulmovista V500 at 20Hz sample frequency, using software V1.3, and exported using the V1.3 software. Recorded around midnight (starting before, ending after 0:00) for testing the time wrapping back to 0. Upright sitting position. Short section of regular breathing. sentec_healthy_volunteer_1a.zri - Recorded using the Sentec LuMon system. Semi-recumbent position. Relatively stable breathing. File 1/2 of recording. sentec_healthy_volunteer_1b.zri - Recorded using the Sentec LuMon system. Semi-recumbent position. Relatively stable breathing. File 2/2 of recording. sentec_healthy_volunteer_2a.zri - Recorded using the Sentec LuMon system. Semi-recumbent position. Relatively stable breathing. File 1/2 of recording. sentec_healthy_volunteer_2b.zri - Recorded using the Sentec LuMon system. Semi-recumbent position. Relatively stable breathing. File 2/2 of recording. timpel_healthy_volunteer_1.txt - Recorded using the Timpel Enlight system. Semi-recumbent position. Sections of stable breathing with movement artifacts. timpel_healthy_volunteer_2.txt - Recorded using the Timpel Enlight system. Semi-recumbent position. Sections of stable breathing with movement artifacts.

提供机构:
Zenodo
创建时间:
2025-11-12
二维码
社区交流群
二维码
科研交流群
商业服务