five

Impact of Over-Expansion on SAPIEN 3 Transcatheter Heart Valve Pericardial Leaflets

收藏
NIAID Data Ecosystem2026-03-11 收录
下载链接:
https://figshare.com/articles/dataset/Impact_of_Over-Expansion_on_SAPIEN_3_Transcatheter_Heart_Valve_Pericardial_Leaflets/11988591
下载链接
链接失效反馈
官方服务:
资源简介:
This study sought to investigate the impact of extensive over-expansion of transcatheter heart valves (THVs) on leaflet structure. THVs may be over-expanded beyond recommended labeling in certain clinical scenarios. However, it is unknown whether over-expansion damages pericardial leaflets. Therefore, we assessed the effect of over-expansion on THV leaflets. SAPIEN 3 THVs (one of each a 23 mm, 26 mm, and 29 mm valve) were expanded to nominal dimensions and then over-expanded to larger than the recommended diameters. Leaflets from a nominally expanded THV were used as control. Structural changes to the leaflets were assessed by histology, scanning electron microscopy (SEM), and second-harmonic generation (SHG) microscopy. Analysis of leaflets by SHG microscopy using texture analysis demonstrated that over-expansion of 23 mm, 26 mm, and 29 mm THVs resulted in significant disorganization of the fibrilar collagen on both aortic and ventricular surfaces (p < 0.05 for all). Histological analysis demonstrated significant thinning of leaflets in over-expanded THVs compared to control (p < 0.05 for over-expanded THVs) as well as a significant increase in pericardial tissue density within the leaflet (p < 0.05 for all over-expanded THVs) compared to control conditions. SEM analysis demonstrated breaks, stretching, and disorganization of collagen fibers within over-expanded THVs. Sequential over-expansion by 1 mm increments up to 3 mm, which is not typically used in clinical practice, of SAPIEN 3 valves on the bench results in damage to the aortic and ventricular surfaces of pericardial leaflets. Whether a lesser degree of over-expansion or degree of over-expansion used clinically will cause similar leaflet injury will require further investigation. AS: Aortic stenosis; A.U.: Arbitrary units; CT: Computed tomography; ECM: Extracellular matrix; GLCM: Gray level co-occurrence matrix (GLCM); H&E: Hematoxylin and eosin; ROI: Region of interest; S3: SAPIEN 3 transcatheter valve; SEM: Scanning electron microscopy; SHG: Second-harmonic generation; TAVR: Transcatheter aortic valve replacement; THV: Transcatheter heart valve
创建时间:
2020-03-16
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作