How complex viscoelastic behaviors within a viscoelastic three-layer structure affect the measurement accuracy of ultrasound viscoelastic creep imaging
收藏DataCite Commons2023-05-11 更新2024-08-18 收录
下载链接:
https://tandf.figshare.com/articles/dataset/How_complex_viscoelastic_behaviors_within_a_viscoelastic_three-layer_structure_affect_the_measurement_accuracy_of_ultrasound_viscoelastic_creep_imaging/19361319/2
下载链接
链接失效反馈官方服务:
资源简介:
The purpose of this study is to use finite element computational simulation to investigate the accuracy of ultrasound viscoelastic creep imaging for evaluating the viscoelastic properties of a heterogeneous viscoelastic three-layer structure. The findings suggest that, in general, viscoelastic creep imaging cannot accurately evaluate the viscoelastic properties of each layer of the viscoelastic three-layer structure. Inaccuracy in the evaluation is due to deviation or distortion of the creep curve of each element within the viscoelastic three-layer structure, resulting from the interaction between complicated viscoelastic behaviors of each layer within the viscoelastic three-layer structure.