遇见数据集

Mid-infrared photo-induced force microscopy (PiF-IR) on model system Bacillus subtilis - vancomycin

收藏
Zenodo2025-10-24 更新2026-05-29 收录
官方服务:

资源简介:

This data set contains raw data used for the manuscript: Title: Nanochemical cell-surface evaluation in photothermal spectroscopic imaging of antimicrobial interactions in model system Bacillus subtilis and vancomycin Authors: Maryam Ali,a,b‡ Robin Schneider,b,c‡ Anika Strecker,b,d Nila Krishnakumar,a,b Sebastian Unger,a,b Mohammad Soltaninezhad,a,b Johanna Kirchhoff,a,b,e Astrid Tannert,a,b,f Katerina A. Dragounova,a,b,e Rainer Heintzmann,a,b Anne-Dorothea Müller,f Christoph Krafft,a,b Ute Neugebauer,a,b,e,f and Daniela Täuber,a,b a Friedrich Schiller University Jena, Jena, Germany.b Leibniz Institute of Photonic Technology, Jena, Germany.c Aalen University of Applied Sciences, Aalen, Germany.d Ernst-Abbe University of Applied Sciences, Jena, Germany.e Jena University Hospital, Jena, Germany.f Jena Biophotonics and Imaging Laboratory, Jena, Germany.g AnfatecInstrumentsAG, Oelsnitz, Germany.‡ These authors contributed equally to this work Content: Two of the series of Bacillus subtilis, which were prepared in the group of Ute Neugebauer at Jena University Hospital, Jena, Germany. Each series contained Bacillus subtilis subso. spizizenii (ATCCTM 633TM). The starter culture (60 ml) was divided into two 30 ml flasks. In one of the flasks, 10 µg/ml vancomycin was added. Treated ("BacVan") and untreated ("Control") Bacillus subtilis were harvested after 15 min, 30 min and 60 min from each flask, dropcasted on CaF2 and investigated using fourier transform infrared spectroscopy (FTIR) and mid-IR photo-induced force microscopy (PIF-IR). The following data sets are available here: Series 2: FTIR data of BacVan and Control harvested after 30 min: FTIR_BacVan_Control_series2.txt PiF-IR data of BacVan harvested after 15 min: BacVan15_series2.zip PiF-IR data of BacVan harvested after 60 min: BacVan60_series2.zip Series 3: PiF-IR data of BacVan harvested after 15 min: BacVan15_series3.zip PiF-IR data of Control harvested after 15 min: Control15_series3.zip PiF-IR data of BacVan harvested after 30 min, overview scan at 1060 cm^-1: BacVan30_series3_1060.zip PiF-IR data of BacVan harvested after 30 min, overview scan at 1520 cm^-1: BacVan30_series3_1520.zip PiF-IR data of BacVan harvested after 30 min, overview scan at 1612 cm^-1 and spectra: BacVan30_series3_spectra.zip PiF-IR data of BacVan harvested after 30 min, zoom scans: BacVan30_series3_zooms.zip PiF-IR data of Control harvested after 30 min, overview scans: Control30_series3_overviews.zip PiF-IR data of BacVan harvested after 60 min, overview scans: BacVan60_series3_overviews.zip PiF-IR data of BacVan harvested after 60 min, zoom position 1: BacVan60_series3_pos1.zip PiF-IR data of BacVan harvested after 60 min, zoom position 2: BacVan60_Series3_pos2.zip

提供机构:
Zenodo
创建时间:
2025-05-15
二维码
社区交流群
二维码
科研交流群
商业服务