Experimental pool boiling heat transfer coefficients of ammonia on two dual-enhanced carbon steel tubes.
收藏DataCite Commons2020-09-20 更新2025-04-16 收录
下载链接:
http://iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0023711&DOCBASE=IFD_REFDOC_EN&SETLANGUAGE=EN
下载链接
链接失效反馈官方服务:
资源简介:
Pool boiling on the external surface of the tubes is a complex process for theoretical analysis, so in many occasions the boiling heat transfer coefficients (HTCs) need to be experimentally determined. Carbon steel tubes are commonly employed in shell-and-tube heat exchangers when ammonia is used as refrigerant, due to their compatibility. This work reports the experimental determination of the ammonia pool boiling HTCs on two dual-enhanced carbon steel tubes of 18.8 mm diameter at saturation temperatures of 10 °C and 0 °C. Experimental facility and data acquisition system are described, experimental procedure is explained, data reduction methodology is detailed, and experimental results are presented and discussed.
提供机构:
International Institute of Refrigeration (IIR)
创建时间:
2018-10-01