The longitudinal reinforcement was lap spliced at the base of the wall. The length of the lap splices was 60 bar diameters. It had boundary-element confinement (1.2% volumetric confining reinforcement ratio). The wall was subjected to lateral displacement reversals of increasing amplitude up to failure. A constant axial load of approximately 10%f'c*Ag was applied.