Specimen W-60-N2: Structural wall with 60db lap splices at the base and without boundary-element confinement subjected to lateral displacement reversals of increasing amplitude up to failure
收藏DataCite Commons2020-08-19 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2011-1050.groups/Experiment-6
下载链接
链接失效反馈官方服务:
资源简介:
The longitudinal reinforcement was lap spliced at the base of the wall. The length of the lap splices was 60 bar diameters. It did not have boundary-element confinement.
The wall was subjected to lateral displacement reversals of increasing amplitude up to failure. A constant axial load of approximately 10%f'c*Ag was applied.
The detail of the ties in this specimen was different from specimens W-MC-C, W-MC-N, W-60-C, and W-40-C (see drawings). The wall has a smaller (1/2 in.) clear spacing between vertical bars in the boundary elements compared to specimens W-60-C, W-60-N, and W-40-C.
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2014-07-15