five

REXCO Project :Physical exercise increases overall brain oscillatory activity but does not influence inhibitory control in young adults|体育锻炼与大脑活动数据集|神经科学研究数据集

收藏
Mendeley Data2024-03-27 更新2024-06-27 收录
体育锻炼与大脑活动
神经科学研究
下载链接:
https://zenodo.org/record/1185067
下载链接
链接失效反馈
资源简介:
Methods and design Participants We recruited 20 young males (19-32 years old, average age 23.8 years old) from the University of Granada (Spain). All participants met the inclusion criteria of normal or corrected to normal vision, reported no neurological, cardiovascular or musculoskeletal disorders, were taking no medication and reporting less than 3 hours of moderate exercise per week. Participants were required to maintain regular sleep-wake cycle for at least one day before each experimental session and to abstain from stimulating beverages or any intense exercise 24 hours before each session. From the 20 participants, one was excluded from the analyses because he did not attend to the last experimental session and another one because of technical issues. Thus, only data from the remaining 18 participants are reported. All subjects gave written informed consent before the study and received 20 euros for their participation. The protocol was approved in accordance with both the ethical guidelines of the University of Granada and the Declaration of Helsinki of 1964. Apparatus and materials All participants were fitted with a Polar RS800 CX monitor (Polar Electro Öy, Kempele, Finland) to record their heart rate (HR) during the incremental exercise test. We used a ViaSprint 150 P cycle ergometer (Ergoline GmbH, Germany) to induce physical effort and to obtain power values, and a JAEGER Master Screen gas analyser (CareFusion GmbH, Germany) to provide a measure of gas exchange during the effort test. Flanker task stimuli were presented on a 21-inch BENQ screen maintaining a fixed distance of 50 cm between the head of participants and the center of the screen. E-Prime software (Psychology Software Tools, Pittsburgh, PA, USA) was used for stimulus presentation and behavioural data collection. Procedure Participants completed two counterbalanced experimental sessions of approximately 120 min each. Sessions were scheduled on different days allowing a time interval of 48–72 hours between them to avoid possible fatigue and/or training effects. On each experimental session (see Fig. 1), participants completed a 15’ resting state period sitting in a comfortable chair with closed eyes. Subsequently, they performed 10’ warm-up on a cycle-ergometer at a power load of 20% of their individual VO2 VAT, following by 30’ exercise at 80% (moderate-intensity exercise session) or at 20% (light intensity exercise session) of their VO2 VAT (see Table 1). Upon completion of the exercise, a 10’ cool down period at 20% VO2 VAT of intensity followed. Each participant set his preferred cadence (between 60-90 rpm • min-1) before the warm-up and was asked to maintain this cadence throughout the session in order to match conditions in terms of dual-task demands. Later, participants waited sitting in a comfortable chair until their heart rate returned to within their 130% of heart rate at resting (average waiting time 5’ 44’’). The first flanker task was then performed for 6’, followed by a 15’ resting period with closed eyes. Finally, they again completed the 6’ flanker task. Flanker task We used a modified version of the Eriksen flanker task based on that reported in Eriksen and Eriksen (1974). The task consisted of a random presentation of a set arrows flanked by other arrows that faced the same or the opposite direction. In the congruent trials, the central arrow is flanked by arrows in the same direction (e.g., <<<<< or >>>>>), while in the incongruent trials, the central arrow is flanked by arrows in the opposite direction (e.g., <<><< or >><>>). Stimuli were displayed sequentially on the center of the screen on a black background. Each trial started with the presentation of a white fixation cross in a black background with random duration between 1000 and 1500 ms. Then, the stimulus was presented during 150 ms and a variable interstimulus interval (1000–1500 ms). Participants were instructed to respond by pressing the left tab button with their left index finger when the central arrow (regardless of condition) faced to the left and the right tab button with their right index finger when the central arrow faced to the right. Participants were encouraged to respond as quick as possible, being accurate. A total of 120 trials were randomly presented (60 congruent and 60 incongruent trials) in each task. Each task lasted for 6 minutes approximately without breaks. EEG recording and analysis EEG data were recorded at 1000 Hz using a 30-channel actiCHamp System (Brain Products GmbH, Munich, Germany) with active electrodes positioned according to the 10-20 EEG International System and referenced to the Cz electrode. The cap was adapted to individual head size, and each electrode was filled with Signa Electro-Gel (Parker Laboratories, Fairfield, NJ). Participants were instructed to avoid body movements as much as possible, and to keep their gaze on the center of the screen during the exercise. Electrode impedances were kept below 10 kΩ. EEG preprocessing was conducted using custom Matlab scripts and the EEGLAB (Delorme & Makeig, 2004) and Fieldtrip (Oostenveld et al., 2011) Matlab toolboxes. EEG data were resampled at 500 Hz, bandpass filtered offline from 1 and 40 Hz to remove signal drifts and line noise, and re-referenced to a common average reference. Horizontal electrooculograms (EOG) were recorded by bipolar external electrodes for the offline detection of ocular artifacts. The potential influence of electromyographic (EMG) activity in the EEG signal was minimized by using the available EEGLAB routines (Delorme & Makeig, 2004). Independent component analysis was used to detect and remove EEG components reflecting eye blinks (Hoffmann and Falkenstein, 2008). Abnormal spectra epochs which spectral power deviated from the mean by +/-50 dB in the 0-2 Hz frequency window (useful for catching eye movements) and by +25 or -100 dB in the 20-40 Hz frequency window (useful for detecting muscle activity) were rejected. On average, 5.1% of epochs per participant were rejected. Spectral power analysis. Processed EEG data from each experimental period (Resting 1, Warm-up, Exercise, Cool Down, Flanker Task 1, Resting 2, Flanker Task 2) were subsequently segmented to 1-s epochs. The spectral decomposition of each epoch was computed using Fast Fourier Transformation (FFT) applying a symmetric Hamming window and the obtained power values were averaged across experimental periods. Event-Related Spectral Perturbation (ERSP) analysis. Task-evoked spectral EEG activity was assessed by computing ERSP in epochs extending from –500 ms to 500 ms time-locked to stimulus onset for frequencies between 4 and 40 Hz. Spectral decomposition was performed using sinusoidal wavelets with 3 cycles at the lowest frequency and increasing by a factor of 0.8 with increasing frequency. Power values were normalized with respect to a −300 ms to 0 ms pre-stimulus baseline and transformed into the decibel scale.
创建时间:
2023-06-28
用户留言
有没有相关的论文或文献参考?
这个数据集是基于什么背景创建的?
数据集的作者是谁?
能帮我联系到这个数据集的作者吗?
这个数据集如何下载?
点击留言
数据主题
具身智能
数据集  4098个
机构  8个
大模型
数据集  439个
机构  10个
无人机
数据集  37个
机构  6个
指令微调
数据集  36个
机构  6个
蛋白质结构
数据集  50个
机构  8个
空间智能
数据集  21个
机构  5个
5,000+
优质数据集
54 个
任务类型
进入经典数据集
热门数据集

中国1km分辨率逐月降水量数据集(1901-2023)

该数据集为中国逐月降水量数据,空间分辨率为0.0083333°(约1km),时间为1901.1-2023.12。数据格式为NETCDF,即.nc格式。该数据集是根据CRU发布的全球0.5°气候数据集以及WorldClim发布的全球高分辨率气候数据集,通过Delta空间降尺度方案在中国降尺度生成的。并且,使用496个独立气象观测点数据进行验证,验证结果可信。本数据集包含的地理空间范围是全国主要陆地(包含港澳台地区),不含南海岛礁等区域。为了便于存储,数据均为int16型存于nc文件中,降水单位为0.1mm。 nc数据可使用ArcMAP软件打开制图; 并可用Matlab软件进行提取处理,Matlab发布了读入与存储nc文件的函数,读取函数为ncread,切换到nc文件存储文件夹,语句表达为:ncread (‘XXX.nc’,‘var’, [i j t],[leni lenj lent]),其中XXX.nc为文件名,为字符串需要’’;var是从XXX.nc中读取的变量名,为字符串需要’’;i、j、t分别为读取数据的起始行、列、时间,leni、lenj、lent i分别为在行、列、时间维度上读取的长度。这样,研究区内任何地区、任何时间段均可用此函数读取。Matlab的help里面有很多关于nc数据的命令,可查看。数据坐标系统建议使用WGS84。

国家青藏高原科学数据中心 收录

CliMedBench

CliMedBench是一个大规模的中文医疗大语言模型评估基准,由华东师范大学等机构创建。该数据集包含33,735个问题,涵盖14个核心临床场景,主要来源于顶级三级医院的真实电子健康记录和考试练习。数据集的创建过程包括专家指导的数据选择和多轮质量控制,确保数据的真实性和可靠性。CliMedBench旨在评估和提升医疗大语言模型在临床决策支持、诊断和治疗建议等方面的能力,解决医疗领域中模型性能评估的不足问题。

arXiv 收录

PCLT20K

PCLT20K数据集是由湖南大学等机构创建的一个大规模PET-CT肺癌肿瘤分割数据集,包含来自605名患者的21,930对PET-CT图像,所有图像都带有高质量的像素级肿瘤区域标注。该数据集旨在促进医学图像分割研究,特别是在PET-CT图像中肺癌肿瘤的分割任务。

arXiv 收录

FAOSTAT Agricultural Data

FAOSTAT Agricultural Data 是由联合国粮食及农业组织(FAO)提供的全球农业数据集。该数据集涵盖了农业生产、贸易、价格、土地利用、水资源、气候变化、人口统计等多个方面的详细信息。数据包括了全球各个国家和地区的农业统计数据,旨在为政策制定者、研究人员和公众提供全面的农业信息。

www.fao.org 收录

中国区域地面气象要素驱动数据集 v2.0(1951-2020)

中国区域地面气象要素驱动数据集(China Meteorological Forcing Data,以下简称 CMFD)是为支撑中国区域陆面、水文、生态等领域研究而研发的一套高精度、高分辨率、长时间序列数据产品。本页面发布的 CMFD 2.0 包含了近地面气温、气压、比湿、全风速、向下短波辐射通量、向下长波辐射通量、降水率等气象要素,时间分辨率为 3 小时,水平空间分辨率为 0.1°,时间长度为 70 年(1951~2020 年),覆盖了 70°E~140°E,15°N~55°N 空间范围内的陆地区域。CMFD 2.0 融合了欧洲中期天气预报中心 ERA5 再分析数据与气象台站观测数据,并在辐射、降水数据产品中集成了采用人工智能技术制作的 ISCCP-ITP-CNN 和 TPHiPr 数据产品,其数据精度较 CMFD 的上一代产品有显著提升。 CMFD 历经十余年的发展,其间发布了多个重要版本。2019 年发布的 CMFD 1.6 是完全采用传统数据融合技术制作的最后一个 CMFD 版本,而本次发布的 CMFD 2.0 则是 CMFD 转向人工智能技术制作的首个版本。此版本与 1.6 版具有相同的时空分辨率和基础变量集,但在其它诸多方面存在大幅改进。除集成了采用人工智能技术制作的辐射和降水数据外,在制作 CMFD 2.0 的过程中,研发团队尽可能采用单一来源的再分析数据作为输入并引入气象台站迁址信息,显著缓解了 CMFD 1.6 中因多源数据拼接和气象台站迁址而产生的虚假气候突变。同时,CMFD 2.0 数据的时间长度从 CMFD 1.6 的 40 年大幅扩展到了 70 年,并将继续向后延伸。CMFD 2.0 的网格空间范围虽然与 CMFD 1.6 相同,但其有效数据扩展到了中国之外,能够更好地支持跨境区域研究。为方便用户使用,CMFD 2.0 还在基础变量集之外提供了若干衍生变量,包括近地面相对湿度、雨雪分离降水产品等。此外,CMFD 2.0 摒弃了 CMFD 1.6 中通过 scale_factor 和 add_offset 参数将实型数据化为整型数据的压缩技术,转而直接将实型数据压缩存储于 NetCDF4 格式文件中,从而消除了用户使用数据时进行解压换算的困扰。 本数据集原定版本号为 1.7,但鉴于本数据集从输入数据到研制技术都较上一代数据产品有了大幅的改变,故将其版本号重新定义为 2.0。CMFD 2.0 的数据内容与此前宣传的 CMFD 1.7 基本一致,仅对 1983 年 7 月以后的向下短/长波辐射通量数据进行了更新,以修正其长期趋势存在的问题。2021 年至 2024 年的 CMFD 数据正在制作中,计划于 2025 年上半年发布,从而使 CMFD 2.0 延伸至 2024 年底。

国家青藏高原科学数据中心 收录