five

fMRI during lower body negative pressure (LBNP) with concurrent physiological measurements

收藏
NIAID Data Ecosystem2026-03-12 收录
下载链接:
https://zenodo.org/record/3885041
下载链接
链接失效反馈
官方服务:
资源简介:
This dataset was acquired at Hannover Medical School, Hanover, Germany. The study complied with the Declaration of Helsinki, and was approved by the local ethics committee (# 3404-2016). All subjects gave written informed consent, and consent to publish their data anonimously. We simulated orthostatic stress by means of lower body negative pressure (LBNP). Negative pressure of 30 mmHg was built up inside a custom-made polycarbonate chamber using a vacuum cleaner and a pressure gauge. The stimulation paradigm consisted of four alternating five-minute blocks, two with and two without negative pressure, starting with the negative pressure. Functional MR images and physiological measures were continuously acquired during this cardiovascular challenge. Transitions between pressure states were excluded to avoid excessive movement.   Data acquisition MRI data All MR images were acquired on a Siemens 3T MAGNETOM Skyra using a 64-channel head/neck coil. The scanning protocol consisted of the following sequences (see Sequences.ods): func_i: Functional whole brain gradient-echo echo-planar images (EPI) (TR=1230 ms; TE=32 ms; 2mm isotropic resolution; simultaneous multi-slice factor=6; partial Fourier=7/8; 4x233 volumes) func_ref: Reference scan for motion correction and template formation; equivalent to func but without multi-band acceleration (TR=7530 ms) SE_AP_PA: Reference scans for unwarping: Two spin-echo images matched to func in distortion without multi-band acceleration; one with the same, the other one with inverted phase encoding direction. t1: T1-weighted magnetisation-prepared rapid acquisition gradient-echo image (MPRAGE) (TR=2300 ms; TE=2.95 ms; TI=900 ms; resolution: 1.1x1.1x1.2 mm3, in-plane acceleration factor=2)   fMRI data preprocessing Our preprocessing pipleine (JPreprocessing) is optimised for the brainstem and hypothalamus by avoiding superfluous resampling steps and unnecessary smoothing. On that account, motion correction (MCFLIRT (Jenkinson et al., 2002)) and unwarping (topup (Andersson et al.,2003)) are applied in a single transformation. Afterwards, brain extraction (BET (Smith, 2002)), grand mean scaling and high pass filtering (0.005 Hz) are applied. The data are not smoothed. Two study templates were generated using Advanced Normalization Tools (ANTs (Avants et al., 2008) using antsMultivariateTemplateConstruction2.sh). The first one using the unwarped EPI reference images (func_ref); the second one using the T1-images. Physiological data The following physiological measures were acquired with an MR-compatible BIOPAC MP150 system Blood pressure (systolic and dyastolic): Non-invasive continuous blood pressure of the digital artery (pulse decomposition analysis using CareTaker) Electrodermal activity Photoplethysmography Respiration (belt) Electrocardiography Subject information 01    m    21 a    182 cm    73 kg    129/62 mmHg 02    f    18 a    167 cm    55 kg    104/58 mmHg 03    m    27 a    200 cm    92 kg    127/62 mmHg 04    f    22 a    160 cm    59 kg    120/73 mmHg 05    f    21 a    170 cm    62 kg    125/67 mmHg 06    f    22 a    171 cm    56 kg    130/70 mmHg 07    f    22 a    174 cm    55 kg    119/61 mmHg 08    f    37 a    171 cm    82 kg    130/71 mmHg 09    m    25 a    170 cm    72 kg    129/62 mmHg 10    f    21 a    173 cm    58 kg    116/71 mmHg 11    m    30 a    185 cm    113 kg    125/65 mmHg 12    f    27 a    157 cm    48 kg    127/76 mmHg 13    m    21 a    184 cm    70 kg    127/80 mmHg 14    f    26 a    173 cm    63 kg    120/68 mmHg 15    m    24 a    200 cm    92 kg    129/72 mmHg 16    m    38 a    196 cm    86 kg    133/67 mmHg 17    m    24 a    186 cm    76 kg    125/65 mmHg 18    f    19 a    178 cm    69 kg    102/53 mmHg 19    f    18 a    168 cm    60 kg    125/66 mmHg 20    f    26 a    171 cm    63 kg    122/70 mmHg 21    f    20 a    175 cm    62 kg    122/76 mmHg 22    f    24 a    169 cm    58 kg    114/64 mmHg Missing data  sub01: physio.acq and physio_cuts.txt sub14: func_3 has 209 time points sub15: func_2 has 167 time points   Data structure Raw data acqparams.txt: Acquisition parameters needed for topup func_i: raw functional data (dummy volumes already deleted) func_ref: Reference image for motion correction and template generation physio.acq: Physiological measurements Trigger Blood pressure (systolic and dyastolic) Electrodermal activity Photoplethysmogram Respiration Electrocardiogram physio_cuts.txt: time points in the physio data that correspond to fMRI blocks (start-time end-time TR #volumes) SE_AP_PA: auxiliary image for unwarping slicetiming_i.txt: Slice timing information in seconds t1: Defaced T1-weighted image. (Undefaced images were used for template generation) Templates and masks EPI-template: Generated from unwarped func_ref images Transformations for all subjects (can be applied using antsApplyTransforms) wb_mask EPI-2-T1: Transformation from EPI to T1-template MNI-template: T1-template warped into MNI_152 hyp_mask lower_bs_mask T1-template: Generated from t1 images hyp_mask lower_bs_mask T1-2-MNI: Transformation from T1 to MNI_152-template JPreprocessing Preprocessing pipeline
创建时间:
2021-10-07
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作