Data for: "Interfacial Concentration Effect Facilitates Heterogeneous Nucleation from Solution"
收藏DataCite Commons2020-08-01 更新2025-04-17 收录
下载链接:
https://pureportal.strath.ac.uk/en/datasets/846b26c2-7040-4c71-b1a8-aa2f9cbe1bba
下载链接
链接失效反馈官方服务:
资源简介:
The dataset presented is split into two sections: experimental and simulation. EXPERIMENTAL In the experimental section you will find a) webcam images used to determine the induction times associated with each experiment, and b) FT-IR spectra of the obtained crytals. Each folder in ~/experimental/ may contain the data associated with one or two experiments as given in the folder names. Experiments that have been performed simultaneously have been combined into one folder. a) Webcam Images Webcam images are contained in ~/experimental/experiment_X/webcam_images FT-IR spectra are contained in ~/experimental/experiment_X/IR_X There are 19 different experimental sets labelled a to s. A readme file is included in folders that contain multiple experiments to state which vials are associated with each experiment. The webcam images from each side of the incubator are labelled A or B, and they are found in folder labelled A or B. In each side there are either 2 or 4 rows of 10 vials. The numerical labelling of vials is from left to right, bottom to top. For example, in the webcam image A/11_01_2019_15_15_04.png the image is from date 11 Jan 2019 and time 15:15:04, and the vials are in the visual order: A31 A32 A33 A34 A35 A36 A37 A38 A39 A40 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 The readme file connects the vial image to the experimental set. For example in folder experimental/experiment_b-c/webcam_images/ we can see from the readme file that vials A1-A20 and B1-B20 are for experimental set b, and vials A21-A40 and B21-B40 are for experimental set c. b) FT-IR spectra FT-IR spectra for each vial that has crystallised is given as a text file labeled using the same system as above. Each file contains two columns: Wavenumber (cm^-1), Absorbance. IR spectra are not available for vials A7, A12-A14, A19, A22, B5-B6 in experiment a. IR spectra are not available for experiment g. SIMULATION The simulation section contains input files used to setup and run the 307 g/kg tridecane-solution interface molecular dynamics simulation. The other simulated systems can be easily reproduced with minor modifications to the files provided. Files used for setting up the system are in ~/simulation/0-setup The system was set up in several steps: 1) generating a layer of tridecane 2) generating a box of glycine and a box of water and combining them to get glycine aqueous solution 3) combining the glycine aqueous solution with the tridecane layer. Step 1 The files in.tridecane and data.tridecane in ~/simulation/0-setup/Step1/ will generate one layer of tridecane as data.oil_slab. Step 2 The files in.glycine and data.glycine in ~/simulation/0-setup/Step2/ will generate a box of glycine molecules. The files in.spce/data.spce in ~/simulation/0-setup/Step2/ will generate a box of water molecules. These boxes can be combined using in.solution in ~/simulation/0-setup/Step2 Step 3 The file in.interface in ~/simulation/0-setup/Step3/ will then combine the data files (data.solution, data.oil_slab) produced in Step 2 to give the final oil-solution interface system. The system is then minimised using in.minimise The system is then run using the files in ~/simulation/1-run/ This folder contains the files for the equilibration and production run of the 307 g/kg oil-solution interface simulation. in.equil and data.minimised_interface will run the equilibration step in.npt and data.equil_interface will run 100 ns of npt production run. The production run periodically generates new datafiles that can be used to continue the production beyond the 100 ns mark.
提供机构:
University of Strathclyde
创建时间:
2020-03-05



