five

The compressive strength of lightweight gypsum composites

收藏
DataCite Commons2026-02-20 更新2026-05-04 收录
下载链接:
https://mostwiedzy.pl/en/open-research-data/the-compressive-strength-of-lightweight-gypsum-composites,220014720220483-0
下载链接
链接失效反馈
官方服务:
资源简介:
The compressive strength of the composites was determined following the PN-EN 196-1 standard. For the tested halves of the rectangular prisms, the pressure plate of the testing machine had dimensions of 40x40 mm, precisely meeting the standards requirements. The loading rate was set at 0.25 N/mm2/s, selected to ensure that failure occurred within 30 to 90 seconds from the start of the test. The flexural compressive was evaluated after 7 days of curing + the time for drying at 40°C.  The data are provided in an .xlsx file and in a corresponding .csv file. A detailed description of the data is included in the respective files. The failure loads are given in kN.
提供机构:
Gdańsk University of Technology
创建时间:
2026-02-20
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作