An evaluation of thermal environment on non-uniform radiant fields.

收藏
DataCite Commons2020-09-18 更新2025-04-16 收录
下载链接:
http://www.iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0016230&DOCBASE=IFD_REFDOC&SETLANGUAGE=FR
下载链接
链接失效反馈
官方服务:
资源简介:
The purpose of the present study is to evaluate the indoor thermal environment under the solar shading environment. In this report, it experimented in the room to which the blind was shut to confirm the indoor thermal environment. Afterwards, the CFD analysis was done, and the accuracy of the analysis was verified compared with experimental measurements. The leakage of heat from the hollow layer between the window and the window shade to the room was confirmed by the measurement result of the experiment. The difference was in the upper and lower temperature distribution in the perimeter zone because of the leakage of heat. Moreover, the leakage of experimental measurements, the temperature, and heat became a roughly corresponding result in the analysis that used CFD.