PurposeFirst, to evaluate inter-rater reliability when human raters estimate the reading performance of visually impaired individuals using the MNREAD acuity chart. Second, to evaluate the agreement between computer-based scoring algorithms and compare them with human rating.MethodsReading performance was measured for 101 individuals with low vision, using the Portuguese version of the MNREAD test. Seven raters estimated the maximum reading speed (MRS) and critical print size (CPS) of each individual MNREAD curve. MRS and CPS were also calculated automatically for each curve using two different algorithms: the original standard deviation method (SDev) and a non-linear mixed effects (NLME) modeling. Intra-class correlation coefficients (ICC) were used to estimate absolute agreement between raters and/or algorithms.ResultsAbsolute agreement between raters was ‘excellent’ for MRS (ICC = 0.97; 95%CI [0.96, 0.98]) and ‘moderate’ to ‘good’ for CPS (ICC = 0.77; 95%CI [0.69, 0.83]). For CPS, inter-rater reliability was poorer among less experienced raters (ICC = 0.70; 95%CI [0.57, 0.80]) when compared to experienced ones (ICC = 0.82; 95%CI [0.76, 0.88]). Absolute agreement between the two algorithms was ‘excellent’ for MRS (ICC = 0.96; 95%CI [0.91, 0.98]). For CPS, the best possible agreement was found for CPS defined as the print size sustaining 80% of MRS (ICC = 0.77; 95%CI [0.68, 0.84]). Absolute agreement between raters and automated methods was ‘excellent’ for MRS (ICC = 0.96; 95% CI [0.88, 0.98] for SDev; ICC = 0.97; 95% CI [0.95, 0.98] for NLME). For CPS, absolute agreement between raters and SDev ranged from ‘poor’ to ‘good’ (ICC = 0.66; 95% CI [0.3, 0.80]), while agreement between raters and NLME was ‘good’ (ICC = 0.83; 95% CI [0.76, 0.88]).ConclusionFor MRS, inter-rater reliability is excellent, even considering the possibility of noisy and/or incomplete data collected in low-vision individuals. For CPS, inter-rater reliability is lower. This may be problematic, for instance in the context of multisite investigations or follow-up examinations. The NLME method showed better agreement with the raters than the SDev method for both reading parameters. Setting up consensual guidelines to deal with ambiguous curves may help improve reliability. While the exact definition of CPS should be chosen on a case-by-case basis depending on the clinician or researcher’s motivations, evidence suggests that estimating CPS as the smallest print size sustaining about 80% of MRS would increase inter-rater reliability.
创建时间:
2019-06-07
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作