[18F]LW223 has low non-displaceable binding in murine brain, enabling high sensitivity TSPO PET imaging
收藏DataCite Commons2024-04-03 更新2024-07-13 收录
下载链接:
https://datashare.ed.ac.uk/handle/10283/8757
下载链接
链接失效反馈官方服务:
资源简介:
Neuroinflammation is associated with a number of brain diseases, making it a common feature of cerebral pathology. Among the best-known biomarkers for neuroinflammation in Positron Emission Tomography (PET) research is the 18 kDa translocator protein (TSPO). This study aims to investigate the binding kinetics of a novel TSPO PETradiotracer, [18F]LW223, in mice and specifically assess its volume of non-displaceable binding (VND) in brain as well as investigate the use of simplified analysis approaches for quantification of [18F]LW223 PET data. Adult male mice were injected with [18F] LW223 and varying concentrations of LW223 (0.003–0.55 mg/kg) to estimate VND of [18F]LW223. Dynamic PET imaging with arterial input function studies and radiometabolite studies were conducted. Simplified quantification methods, standard uptake values (SUV) and apparent volume of distribution (VTapp), were investigated. [18F]LW223 had low VND in the brain (<10% of total binding) and low radiometabolism ( 15–20%). The 2-tissue compartment model provided the best fit for [18F]LW223 PET data, although its correlation with SUV90–120min or VTapp allowed for [18F] LW223 brain PET data quantification in healthy animals while using simpler experimental and analytical approaches. [18F] LW223 has the required properties to become a successful TSPO PET radiotracer.
提供机构:
University of Edinburgh. Centre for Cardiovascular Science
创建时间:
2024-04-03