i3M data for A4IM project

收藏
Zenodo2026-06-15 更新2026-05-26 收录
官方服务:

资源简介:

The images obtained at i3M (Valencia, Spain) has been acquired in a MRI prototype called Physio1. This system is a compact low-field MRI scanner based on a 72 mT Halbach permanent magnet, with a total weight of 250 kg. It is conceived as a portable and low cost (<50 k€) system, suitable for operation indoors, outdoors, and even at a patient’s home, and specifically designed for musculoskeletal imaging, particularly of joints, arms, and legs. The control system is built upon the MaRCoS project and is managed using a RedPitaya 122-16 together with an OCRA1 board, enabling flexible pulse sequence development and hardware control. User interaction with the system is performed through the MARGE environment. Physio1 is equipped with three cylindrical gradient coils capable of delivering gradient strengths of 25 mT/m along the x-axis and 40 mT/m along the y- and z-axes. For knee imaging, the system employs two single-channel RF coil designs based on Litz wire—one stretchable and one rigid—both used for transmission and reception. The qualitative data here presented have been acquired using the streachable coil, meanwhile data for relaxation mapping was measured using the rigid model. All the data were generated using seven volunteers. Anonymized information on the sex, age, height, and possible knee injuries of the volunteers scanned for this database is provided below. The subject numbering used here corresponds to the numbering specified in the folder and file names of this database.Subject 1: Female. 34 years. 170 cm. Without injuries/anomalies in any knee.Subject 2: Female. 27 years. 160 cm. Without injuries/anomalies in any knee.Subject 3: Male. 31 years. 174 cm. Baker cyst in the upper region of left knee.Subject 4: Male. 24 years. 185 cm. Without injuries/anomalies in any knee.Subject 5: Male. 24 years. 185 cm. Remanences of Osgood-Schlatter in right knee.Subject 6: Male. 30 years. 172 cm. Slight wear of both menisci due to sports practices.Subject 7: Female. 36 years. 160 cm. Without injuries/anomalies in any knee. For a given subject acting as a volunteer, we distinguish between the application of (a) a qualitative protocol and (b) a quantitative protocol. The qualitative protocol consists of running three consecutive 3D RARE sequences, conveniently optimized to obtain PD-, T1-, and T2-weighted images. This protocol requires approximately 25 minutes of sequence execution time. The quantitative protocol consists of acquiring two sets of images: (1) five 3D RARE sequences with varying effective echo times (TEeff) to obtain a three-dimensional T2 map, and (2) seven 3D STIR sequences with varying inversion times to obtain a T1 map. Each image set is acquired for the same subject in separate sessions due to the long scanning times required for the quantitative protocol. In the tables below are listed the main parameters of the sequences performed for both protocols. Table 1. Sequence parameters for qualitative protocol PD-w T1-w T2-w Naverages 1 8 2 FOV (cm) (24, 18, 16) (24, 18, 16) (24, 18, 16) Matrix size (160, 120, 32) (160, 120, 32) (160, 120, 32) Resolution (mm) (1.5, 1.5, 5) (1.5, 1.5, 5) (1.5, 1.5, 5) {Rd, Ph, Sl} {x,y,z} {x,y,z} {x,y,z} ETL 4 6 10 RF phase convetion CPMG CPMG CPMG TE/TEeff (ms) 10/10 20/20 20/100 k-Space trayectory Center-out Center-out Out-center Inversion time (ms) 0 0 0 Repetition time (ms) 800 150 1000 Acquisition time (ms) 4 4 4 BWacq (kHz) 40 40 40 Dummy pulses 5 20 0 Greph, rd time (ms) 5.5 5.5 5.5 Gdep, rd time (ms) 1 1 1 Gdep, ph/sl time (ms) 1 1 1 Slice zero filling (%) 35 35 35 Tscan (min) 8.3 8.3 8.3 Table 1. Sequence parameters for quantitative protocol 3D STIR for T1 mapping 3D RARE for T2 mapping Naverages 1 1 FOV (cm) (24, 18, 16) (24, 18, 16) Matrix size (160, 120, 32) (160, 120, 32) Resolution (mm) (1.5, 1.5, 5) (1.5, 1.5, 5) {Rd, Ph, Sl} {x,y,z} {x,y,z} ETL 4 4 TE (ms) 10 {10, 25, 50, 75, 100} TEeff 10 {10, 25, 50, 75, 100} k-Space trayectory Center-out Center-out Inversion time (ms) {0, 40, 80, 120, 160, 200, 500} 0 Repetition time (ms) 800 800 Tacq (ms) 4 4 BWacq (kHz) 40 40 Dummy pulses 5 5 Greph, rd time (ms) 5.5 5.5 Gdep, rd time (ms) 1 1 Gdep, ph/sl time (ms) 1 1 Slice zero filling (%) 35 35 Tscan (min) 8.3 8.3 Number of images 7 5 Tprotocol (min) 58 41 Deeper details can be found in the couple of files attached here: 1) Useful information for data users.pdf 2) In vivo imaging with MRILab’s Physio 1 Scanner

提供机构:
Zenodo
创建时间:
2026-02-03
二维码
社区交流群
二维码
科研交流群
商业服务