Cold-Atom Buoy: A Differential Magnetic Sensing Technique in Cold Quadrupole Traps
收藏DataCite Commons2026-04-13 更新2026-04-25 收录
下载链接:
https://hdl.handle.net/21.15109/ARP/HQN8RT
下载链接
链接失效反馈官方服务:
资源简介:
We present a differential technique for vector magnetic sensing based on a cold- atom cloud in a magnetic quadrupole trap. An external homogeneous magnetic field displaces the trap center in a direction and magnitude proportional to the field. By reversing the quadrupole polarity between experimental shots and comparing the resulting cloud positions, we extract a differential displacement signal that is free from common-mode effects such as gravity and weak magnetic- field inhomogeneities. The signal is directionally proportional to the external field and requires only absorption imaging, without spectroscopic interrogation. Assuming micron-scale position resolution, the technique enables field resolution at the milli-Gauss level. It offers a practical tool for field compensation in magnetically sensitive experimental stages, bridging operational regimes from Earth-level fields to atomic magnetometry. A straightforward extension to full three-dimensional sensing is possible with only a minimal addition to standard cold-atom infrastructure.