Intra-abdominal pressure is a significant physiological parameter influencing spinal stability and pelvic floor health. This study investigates the potential of a transformer encoder model to predict IAP using motion capture data and musculoskeletal modeling. Data from 211 subjects performing walking, fast walking, and running were used to train a transformer encoder. The model showed promising results with an overall Mean Absolute Percentage Error of 13.5% and a Pearson correlation coefficient of 0.85. Predictions for fast walking and running proved to be more challenging compared to walking, which was attributed to the greater variability and complexity of faster movements.