Enhanced removal of Nickel (II) from aqueous solutions by SDS-functionalized graphene oxide
收藏data.ncl.ac.uk2016-05-31 更新2025-01-09 收录
下载链接:
https://data.ncl.ac.uk/articles/dataset/Enhanced_removal_of_Nickel_II_from_aqueous_solutions_by_SDS-functionalized_graphene_oxide/10281602/2
下载链接
链接失效反馈官方服务:
资源简介:
Adsorption experiments were conducted by stirring known amounts of Graphene Oxide (GO)
or SDS-functionalized Graphene Oxide (GO-SDS) (ranging from 10 to 100 mg) with 25 mL of aqueous Ni (II) solutions (at concentrations ranging from 5 to 40 mg/L) for predetermined time intervals at room temperature (298 K).The concentrations of the Ni (II) solutions were measured by Inductively Coupled Plasma
Optical Emission Spectroscopy (ICP-OES / UNICAM 701 Series Emission Spectrometer) and
a UV-Visible spectrophotometer (Cary 100 UV-Vis) by applying the Dimethylglyoxime method [28]. Fourier transform infrared (FTIR) spectra of the samples were recorded with a Varian 800 FTIR spectrometer
本研究通过室温(298 K)下搅拌已知量的氧化石墨烯(GO)或SDS功能化氧化石墨烯(GO-SDS)(质量范围为10至100毫克)与25毫升不同浓度的水溶性Ni(II)溶液(浓度范围为5至40毫克/升)进行吸附实验。Ni(II)溶液的浓度通过电感耦合等离子体光学发射光谱法(ICP-OES / UNICAM 701系列发射光谱仪)以及紫外-可见分光光度计(Cary 100 UV-Vis)并采用二甲基乙二醛法[28]进行测定。样品的傅里叶变换红外光谱(FTIR)由Varian 800 FTIR光谱仪记录。
提供机构:
Newcastle University