Table_1_The feasibility and safety of combining atrial septal defect/patent foramen ovale and left atrial appendage closure: A systematic review and meta-analysis.docx
收藏NIAID Data Ecosystem2026-03-14 收录
下载链接:
https://figshare.com/articles/dataset/Table_1_The_feasibility_and_safety_of_combining_atrial_septal_defect_patent_foramen_ovale_and_left_atrial_appendage_closure_A_systematic_review_and_meta-analysis_docx/21830013
下载链接
链接失效反馈官方服务:
资源简介:
IntroductionAtrial Septal Defect/Patent Foramen Ovale (ASD/PFO) occlusion is performed to prevent paradoxical embolism and reduce the risk of recurrent ischemic stroke. Left atrial appendage (LAA) closure is used as an alternative to medical therapy of non-valvular atrial fibrillation for prevention of stroke. Multiple studies have examined performing LAA and ASD/PFO occlusion. However, the feasibility and safety of combined occlusion of the left atrial appendage and ASD/PFO are not clear, furthermore, these studies are limited by their small sample sizes and retrospective analysis. In this study, we aimed to systematically review and meta-analyze the feasibility and safety of combining left atrial appendage and ASD/PFO closure.
MethodsPubMed, Web of Science, CNKI, Cochrane Library, Embase, and WanFang database were searched up to April 2022 to identify peer-reviewed human studies on assessing the feasibility, safety, and efficacy of combining left atrial appendage and ASD/PFO closure. The primary outcome was calculated: procedural feasibility outcome and procedural safety outcome.
ResultsA total of 10 articles, including 340 patients from multiple countries, were included in the analysis. The principal findings of our study are: compared with single LAA closure, (i) combining PFO/ASD occlusion and LAA closure had similar procedural success proportion (98.43%, 95% CI: 96.67–100.00%), (ii) similar safety event incidences developed (1.67%, 95% CI: 0.24–3.92%), subgroup analyzed safety event incidences in death was 0.00 (95% CI: 0.00–0.33%), cardiac tamponade was 0.87% (95% CI: 0.00–2.77%), device embolization was 0.00 (95% CI: 0.00–0.60%), major bleeding was 0.00 (95% CI: 0.00–0.33%), stroke was 0.00 (95% CI: 0.00–0.02%).
ConclusionAlthough this systematic review and meta-analysis demonstrate the technical feasibility and safety of combining closure of PFO/ASD and LAA, further studies of sufficient sample size, long-term follow-up, and rigor endpoint criteria are yet needed to fully evaluate this combination procedure for its role in clinical outcomes.
创建时间:
2023-01-06



