five

METAL ION RELEASE ACCORDING TO LEG LENGTH DISCREPANCY IN CERAMIC-ON-METAL HIP ARTHROPLASTY

收藏
Figshare2023-07-01 更新2026-04-28 收录
下载链接:
https://figshare.com/articles/dataset/METAL_ION_RELEASE_ACCORDING_TO_LEG_LENGTH_DISCREPANCY_IN_CERAMIC-ON-METAL_HIP_ARTHROPLASTY/23648199
下载链接
链接失效反馈
官方服务:
资源简介:
ABSTRACT Objective The ceramic-on-metal (CoM) bearing has the theoretical advantages over ceramic-on-ceramic (CoC) and metal-on-metal bearings. This study aimed to analyze factors affecting the metal ion release of CoM bearings and compare clinical performance with CoC bearings. Methods The 147 patients were divided into 96 patients in group 1 (CoM group) and 51 patients in group 2 (CoC group). Additionally, within group1, 48 patients and 30 patients were sub-categorized into group 1-A with leg length discrepancy (LLD) less than 1cm and group 1-B greater than 1 cm. The level of serum metal ions, functional scores and plain radiographs were obtained for the analysis. Results The level of cobalt (Co) 2-years after surgery and chromium (Cr) 1-year after surgery showed significantly higher in the group1 than the group2. LLD indicated statistically significant positive correlation between serum metal ion levels among CoM bearing THAs. In comparison of the average metal ions level changes, group 1-B showed higher level of metal ion than group 1-A. Conclusion In patients underwent THA with CoM bearings, large LLD have a higher risk of complications associated to metal ions. Therefore, it is critical to reduce the LLD to 1 cm or less in using CoM bearing. Level of Evidence III; Case Control Study.
创建时间:
2023-07-01
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作