Effect of sonic and ultrasonic activation on physicochemical properties of root canal sealers
收藏Figshare2019-09-01 更新2026-04-29 收录
下载链接:
https://figshare.com/articles/dataset/Effect_of_sonic_and_ultrasonic_activation_on_physicochemical_properties_of_root_canal_sealers/9796025
下载链接
链接失效反馈官方服务:
资源简介:
Abstract Objective: To evaluate the effect of ultrasonic and sonic activation on physicochemical properties of AH Plus, MTA Fillapex, ADSeal, GuttaFlow Bioseal, and GuttaFlow 2 sealers. Methodology: Three experimental groups were formed: no activation (NA), ultrasonic activation (UA), and sonic activation (SA). The sealers were manipulated according to the manufacturers’ instructions. A 3-mL syringe was adapted to receive 1 mL of sealer. Activation was performed with a 20/.01 ultrasonic insert (20 s/1W) in the UA group. A size 35.04 sonic tip was used (20 s/10,000 cycles/min-1) in the SA group. The molds for physicochemical analysis were filled and evaluated according to ANSI/ADA specification no. 57: setting time (ST), flow (FL), dimensional change (DC), solubility (SB), and radiopacity (RD). Statistical analysis was performed by Kruskal-Wallis, one-way ANOVA, and Tukey's tests (P
创建时间:
2019-09-01