five

Visual working memory: Study two Task fMRI and Behavioural response

收藏
OpenNeuro2018-12-31 更新2026-03-14 收录
下载链接:
https://openneuro.org/datasets/ds001635
下载链接
链接失效反馈
官方服务:
资源简介:
Subjects and MRI protocol ------------------------------------- Sixteen right-handed healthy adults (11 female, mean age 23.938, range 19-41 years of age) participated in this study on the same 3 T MRI scanner (TrioTim, software version syngo MR B17, Siemens, London,Ontario,Canada) by acquiring: - axial 3D T1-weighted images usign an MPRAGE sequence [echo time (TE) = 2.9 ms, inversion time = 900 ms, flip angle = 9°, slice thickness=1 mm, matrix size=256 x 240 x 384; - three runs of bold task fMRI images using a T2*-weighted echo-planar imaging (EPI) sequence (TR=2000 ms, TE=30 ms, flip angle=60°, slice thickness=3 mm; FOV=240 mm×240 mm, matrix size 80×80; number of slices=36; interleaved slice acquisition). Task protocol ------------------------------------ Participants were required to encode and maintain a set of features from an array of compound stimuli, composed of a pseudo-randomly selected numbers placed at random spatial positions within a 4 * 4 grid. Each trial began with a pre-encoding cue directing participants to focus on features from one of these two stimulus domains (number or spatial). Then, three, or six compound stimuli were presented within the 4 * 4 grid. After 10 seconds of encoding, stimuli were removed, and A second retro-cue was added to cue the participants to either manipulate (add 3 or mentally rotate 90 clockwise the spatial pattern) or simply maintain the encoded information for 10 seconds. Subsequently, participants were presented with a probe array where one of the numbers and locations had been shuffled. They were required to indicate within a 10s timeframe the location of the shuffled item that was within the currently maintained domain. The trial terminated at the point in time when the participant responded and the next trial began after a 10-second inter-trial-interval (ITI), during which a fixation cross was displayed and they were instructed to rest. In the imaging analysis, this (ITI) provided the baseline for comparing all other events, i.e., where no overt processing of the WM task was required. Defacing ------------------------------------ spm_deface was used on all anatomical images to ensure de-identification of subjects.
创建时间:
2018-12-31
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作