遇见数据集

IDF EnergyPlus files of an existing Danish apartment block and eight retrofit scenarios

收藏
Mendeley Data2017-02-20 更新2026-04-09 收录
官方服务:

资源简介:

This data provides nine detailed EnergyPlus files of an existing four-story apartment block located in Aarhus, Denmark. The third floor is modelled, which consist of five stairwells and ten apartments. The files can be used for building performance simulation and co-simulation with the building controls virtual test bed. The data contains IDF EnergyPlus files [3] of the third floor of an existing Danish four-story apartment block and eight retrofit scenarios. The block was built in 1978 and has only undergone minor refurbishments since then. The floor consists of five stairwells and ten apartments: one 1-room apartment (Apt. 9), four 3-room apartments (Apt. 1, 3, 5 and 7) and five 4-room apartments (Apt. 2, 4, 6, 8 and 10) with east-west oriented facades where the west oriented facades has unheated balconies. The stairwells and apartments were modelled as individual thermal zones with adiabatic horizontal surfaces (floor and roof). The stairwells are kept at a minimum temperature of 15°C. Further specification of geometry, materials and constructions can be found in the references [1] and [2]. The files can be used for building performance simulation and co-simulation with building controls virtual test bed [4, 5]. [1] T. H. Pedersen, R. E. Hedegaard, and S. Petersen, “Space heating demand response potential of retrofitted residential apartment blocks”, Energy and Buildings (2017). [2] R. E. Hedegaard, T. H. Pedersen, and S. Petersen, “Multi-market demand response using economic model predictive control of space heating in residential buildings”, Energy and Buildings (2017). [3] U.S. Department of Energy, “EnergyPlus 8.1.0,” [Online]. [4] Lawrence Berkeley National Laboratory, “Buildings Control Virtual Test Bed - BCVTB (1.4.0),” [Online]. [5] M. Wetter, “Co-simulation of building energy and control systems with the Building Controls Virtual Test Bed,” Journal of Building Performance Simulation (2010), vol. 3, no. 4, pp. 1-19, DOI: 10.1080/19401493.2010.518631.

本数据集包含9份详细的EnergyPlus建筑能耗模拟文件,对应丹麦奥胡斯市一栋现存的四层公寓楼。本次建模针对该公寓楼的三楼,该楼层包含5个楼梯间与10套公寓。 本数据集文件可用于建筑性能模拟,以及与建筑控制虚拟测试平台(Buildings Controls Virtual Test Bed, BCVTB)的联合仿真。 数据集包含该丹麦四层公寓楼三楼的IDF(EnergyPlus输入数据文件)文件[3],以及8种翻新改造场景。该公寓楼建于1978年,此后仅进行过少量翻新作业。 该三楼的10套公寓具体包括:1套1居室公寓(编号9)、4套3居室公寓(编号1、3、5、7),以及5套4居室公寓(编号2、4、6、8、10);其外立面呈东西向布置,西侧外立面带有未供暖阳台。 建模过程中,楼梯间与公寓均被设置为独立热区,水平表面(楼板与屋顶)采用绝热边界条件。楼梯间维持最低15℃的室内温度。 更多关于几何模型、材料与构造的细节可参见参考文献[1]与[2]。本数据集文件可用于建筑性能模拟,以及与建筑控制虚拟测试平台[4,5]的联合仿真。 [1] T. H. Pedersen, R. E. Hedegaard, and S. Petersen, "Space heating demand response potential of retrofitted residential apartment blocks", Energy and Buildings (2017). [2] R. E. Hedegaard, T. H. Pedersen, and S. Petersen, "Multi-market demand response using economic model predictive control of space heating in residential buildings", Energy and Buildings (2017). [3] U.S. Department of Energy, "EnergyPlus 8.1.0," [Online]. [4] Lawrence Berkeley National Laboratory, "Buildings Control Virtual Test Bed - BCVTB (1.4.0)," [Online]. [5] M. Wetter, "Co-simulation of building energy and control systems with the Building Controls Virtual Test Bed," Journal of Building Performance Simulation (2010), vol. 3, no. 4, pp. 1-19, DOI: 10.1080/19401493.2010.518631.

创建时间:
2017-02-20
二维码
社区交流群
二维码
科研交流群
商业服务