five

Far-infrared tangential interferometer/polarimeter design and installation for NSTX-U

收藏
DataCite Commons2020-07-30 更新2025-04-09 收录
下载链接:
https://www.osti.gov/servlets/purl/1562051/
下载链接
链接失效反馈
官方服务:
资源简介:
The Far-infrared Tangential Interferometer/Polarimeter (FIReTIP) system has been refurbished andis being reinstalled on the National Spherical Torus Experiment-Upgrade (NSTX-U) to supplyreal-time line-integrated core electron density measurements for use in the NSTX-U plasma controlsystem (PCS) to facilitate real-time density feedback control of the NSTX-U plasma. Inclusionof a visible light heterodyne interferometer in the FIReTIP system allows for real-time vibrationcompensation due to movement of an internally mounted retroreflector and the FIReTIP front-endoptics. Real-time signal correction is achieved through use of a National Instruments CompactRIOfield-programmable gate array.
提供机构:
Princeton Plasma Physics Laboratory (PPPL), Princeton, NJ (United States)